Skip to Content.
The following is a list of links that will jump to news, featured sites, A-Z directory, and Governor Bredesen's site. Skip to State News. Skip to Featured Sites. Skip to A-Z Directory. Skip to Governor Bredesen's Site.
Link back to General Services main page.
The following are the section navigation links.

Purchasing Division

Contracts

ACTIVE STATEWIDE CONTRACTS (SWC)

Search Contracts

Last Updated 05/24/10, 08:06:08
SWC No.: 206 Title: SPREADERS, SALT, UTILITY TYPE
Contract Period From: 12/01/09 To: 11/30/10 Commodity Code Number: 765-54

Contact the following in the order named in the event of questions pertaining to this contract.
Contract Administrator and Phone: RICHARD HAUSLER (615)741-6770
Buyer Supervisor and Phone: JOAN GILBERT (615)741-7907


The following terms, listed either partially or in their entirety, pertain to all individual contracts under this SWC number. Specifications, if present, will follow the terms and conditions. Please refer to the actual contract document for the entire list of the terms and conditions and complete specifications.

F.O.B. DESTINATION (STATEWIDE CONTRACT)

F.O.B. DESTINATION FOR SHIPMENT TO:

ALL STATE AGENCIES, LOCAL GOVERNMENT AGENCIES AND AUTHORIZED
NON-PROFIT ENTERPRISES LOCATED WITHIN THE STATE OF TENNESSEE.

TERM OF CONTRACT

THE ANTICIPATED EFFECTIVE DATE AND EXPIRATION DATE OF THE CONTRACT ARE
SHOWN ON THE FRONT OF THIS SOLICITATION. IF AWARD HAS NOT BEEN MADE BY
THE ANTICIPATED EFFECTIVE DATE, THEN THE CONTRACT SHALL BECOME
EFFECTIVE UPON THE DATE THE BID IS ACCEPTED AND CONTRACT AWARDED BY
THE STATE, AS INDICATED BY THE PURCHASING AGENT'S SIGNATURE ON THE
CONTRACT NOTICE OF AWARD (NOTE: THE CHANGE OF EFFECTIVE DATE MAY NOT
RESULT IN A CHANGE OF THE ANTICIPATED EXPIRATION DATE.)

RENEWAL OPTIONS: THIS CONTRACT MAY BE RENEWED UPON SATISFACTORY
COMPLETION OF THE INITIAL CONTRACT TERM. THE STATE RESERVES THE RIGHT
TO EXECUTE UP TO 1 OPTION TO RENEW THIS CONTRACT ANNUALLY UNDER THE
SAME TERMS AND CONDITIONS FOR A PERIOD NOT TO EXCEED 12 MONTHS EACH BY
THE STATE. IT IS MUTUALLY UNDERSTOOD AND AGREED THAT THE STATE'S
COMMITMENT IS LIMITED TO A BASE TERM CONTRACT, NOT TO EXCEED TWELVE
(12) MONTHS, WHICH IS SUBJECT TO RENEWAL ANNUALLY AT THE STATE'S SOLE
OPTION.

IT IS UNDERSTOOD AND AGREED THAT THE STATE RESERVES THE RIGHT TO
EXTEND THE TERM CONTRACT PERIOD RESULTING FROM THIS SOLICITATION AN
ADDITIONAL PERIOD OF TIME, NOT TO EXCEED 180 DAYS BEYOND THE NORMAL
EXPIRATION DATE OF SUCH CONTRACT, UPON MUTUAL WRITTEN AGREEMENT BY
BOTH PARTIES, UNDER THE SAME TERMS AND CONDITIONS. PROVIDED, HOWEVER,
IN NO EVENT SHALL THE MAXIMUM TERM OF A CONTRACT EXCEED A TOTAL OF
SIXTY (60) MONTHS.
VOLUME, MULTI-YEAR

THE TOTAL PURCHASES OF ANY INDIVIDUAL ITEM ON THE CONTRACT ARE NOT
KNOWN. THE PURCHASING DIVISION HAS ATTEMPTED TO GIVE AN ACCURATE
ESTIMATE OF PROBABLE PURCHASES OF EACH ITEM FROM THE CURRENT CONTRACT
PERIOD AND PROJECTED ESTIMATES FOR THE NEW CONTRACT PERIOD. THE
PURCHASING DIVISION DOES NOT GUARANTEE THAT THE STATE WILL BUY ANY OR
ALL ESTIMATED AMOUNTS OF ANY SPECIFIED ITEM OR ANY TOTAL AMOUNT.

1ST 12 MONTHS $ 299,268.12
2ND 12 MONTHS $ 299,268.12




CURRENT CONTRACT PERIOD 08/31/08 THROUGH 09/01/09 $ 139,947.86

CONTRACTOR WILL ONLY BE PAID FOR SERVICES RENDERED HEREUNDER PURSUANT
TO PURCHASE ORDER RELEASES ISSUED TO CONTRACTOR FROM THE STATE.
CONTRACTOR IS NOT ENTITLED TO BE PAID THE MAXIMUM LIABILITY FOR ANY
ONE YEAR UNDER THE CONTRACT OR ANY EXTENSIONS OF THE CONTRACT FOR WORK
NOT REQUESTED BY THE STATE. MAXIMUM LIABILITY REPRESENTS AVAILABLE
FUNDS FOR PAYMENT TO CONTRACTOR AND DOES NOT GUARANTEE PAYMENT OF ANY
SUCH FUNDS TO THE CONTRACTOR PER YEAR UNDER THIS CONTRACT UNLESS THE
STATE REQUESTS WORK AND CONTRACTOR PERFORMS SAID WORK. THE STATE IS
UNDER NO OBLIGATION TO REQUEST WORK FROM CONTRACTOR IN ANY SPECIFIC
DOLLAR AMOUNTS PER YEAR UNDER THIS CONTRACT AND THE STATE MAY NOT
REQUEST ANY WORK AT ALL FROM CONTRACTOR DURING ONE YEAR PERIOD.
DELIVERY TIME (DAYS)

ALL ITEMS MUST BE DELIVERED WITHIN APPROXIMATELY 120 DAYS AFTER
RECEIPT OF A PURCHASE ORDER.

FREIGHT F.O.B. STATE AGENCY (DOCK)

ALL QUOTATIONS SHALL BE F.O.B. DESTINATION. THE TERM F.O.B. SHALL MEAN
DELIVERED AND UNLOADED ONTO THE RECEIVING DOCK OF THE AGENCY LISTED,
WITH ALL CHARGES FOR TRANSPORTATION AND UNLOADING PREPAID BY THE
VENDOR/CONTRACTOR.

FIRM BID PRICE PERIOD (PRICE INCREASE ALLOWED AFTER TIME FRAME)

PRICES QUOTED SHALL BE FIRM FOR 365 DAYS FOLLOWING THE DATE OF THE
AWARD, EXCEPT THE STATE SHALL BE ADVISED OF, AND RECEIVE THE BENEFIT
OF, ANY PRICE DECREASE IN EXCESS OF FIVE (5) PERCENT AUTOMATICALLY.
THE VENDOR/CONTRACTOR MUST PROVIDE WRITTEN PRICE REDUCTION INFORMATION
WITHIN TEN (10) DAYS OF ITS EFFECTIVE DATE.

REQUESTS FOR PRICE CHANGES BASED ON VENDOR/CONTRACTOR'S COST:

WRITTEN REQUESTS FOR PRICE CHANGES IN TERM CONTRACTS BASED ON VENDOR/
CONTRACTOR'S ACTUAL COST FOR OTHER THAN AN IMPOSED CHARGE BY FEDERAL,
STATE, COUNTY, OR CITY GOVERNMENT ENTITY AFTER THE FIRM PRICE PERIOD
SHALL BE SUBMITTED IN WRITING TO THE DEPARTMENT OF GENERAL SERVICES,
PURCHASING DIVISION. ANY INCREASE SHALL BE BASED ON THE CONTRACT
HOLDER'S ACTUAL COST INCREASE AND MAY NOT CONSTITUTE ADDITIONAL
PROFIT, AS SHOWN IN WRITTEN DOCUMENTATION SUCH AS INVOICES CLEARLY
DEMONSTRATING AN INCREASE IN COST COMPONENTS UPON WHICH ORIGINAL BID
OR LAST PRICE INCREASE WAS BASED, I.E. INVOICES FOR THE COST OF
MATERIALS, LABOR, DELIVERY, ETC., OR LABOR UNION AGREEMENTS FROM THE
START OF THE CONTRACT OR FIRM BID PRICE PERIOD AND CURRENT DATE AND/OR
A SIGNED LETTER FROM THE CONTRACT HOLDER'S SUPPLIER STATING THAT IT
HAS OR WILL BE IMPOSING A SPECIFIED DOLLAR AMOUNT OR A PERCENTAGE
INCREASE FOR ALL OF ITS CUSTOMERS. IF DOCUMENTATION IS FROM VENDOR/
CONTRACTOR'S SUPPLIER, VENDOR/CONTRACTOR MUST SHOW PROOF THAT IT HAS
TRIED TO OBTAIN THE GOODS FROM OTHER SUPPLIERS AND WAS UNABLE TO GET
IT AT ANY LOWER PRICE. ALL REQUESTS FOR PRICE INCREASES MUST BE
SUBMITTED IN WRITING.

IN ORDER FOR THE PURCHASING DIVISION TO APPROVE THE CONTRACT HOLDER'S
REQUEST FOR A PRICE INCREASE, ITS NEW BID PRICE(S) MUST STILL BE THE
LOW BID MEETING SPECIFICATIONS; THIS WILL BE DETERMINED BY USING THE
ORIGINAL EVALUATION MODEL WITH THE PRICES FROM THE NEW LIST PRICE.
IF THE CONTRACT HOLDER'S NEW BID PRICE IS HIGHER THAN THE NEXT LOW
BIDDER, PURCHASING DIVISION WILL EVALUATE THE NEXT LOW BID TO
DETERMINE IF IT MEETS SPECIFICATIONS AND IF SO, WILL ASK IF THE NEXT
LOW BIDDER IS WILLING TO HONOR ITS BID PRICES FOR POSSIBLE RE-AWARD.

IF THE NEXT LOW BIDDER AGREES TO HONOR ITS BID PRICE AND WILL HOLD IT
FOR THE FIRM BID PRICE PERIOD FOLLOWING AWARD, PURCHASING DIVISION
WILL APPRISE THE CONTRACT HOLDER OF THE SITUATION AND ASK IF IT WANTS
TO CONTINUE WITH ITS PRICE INCREASE REQUEST OR WITHDRAW ITS PRICE
INCREASE REQUEST. IF THE CONTRACT HOLDER STATES THAT IT WANTS TO
CONTINUE WITH ITS REQUEST FOR A PRICE INCREASE, PURCHASING DIVISION
WILL RECOMMEND CANCELLATION OF THE CONTRACT AND RE-AWARD TO THE NEXT
LOW BIDDER.

AT THE OPTION OF THE STATE, (1) REQUEST MAY BE GRANTED, (2) THE
CONTRACT MAY BE CANCELED AND AWARDED TO THE NEXT LOW BIDDER, (3)
THE CONTRACT MAY BE CANCELED AND THE COMMODITY/SERVICE BE READVERTISED
FOR AWARD, OR (4) CONTINUE THE CONTRACT WITHOUT CHANGE.
THE PURCHASING DIVISION WILL ACCEPT OR REJECT ALL SUCH WRITTEN
REQUESTS WITHIN FORTY-FIVE (45) WORKING DAYS OF THE DATE OF RECEIPT
OF COMPLETE AND VERIFIED DOCUMENTATION.

APPROVAL OF PRICE INCREASES

IF APPROVED, THE PURCHASING DIVISION WILL MODIFY THE CONTRACT TO
REFLECT THE APPROVED PRICE INCREASE, PRINT AND MAIL THE REVISED
CONTRACT. THE CONTRACT HOLDER SHALL HONOR ALL PURCHASE ORDERS
DATED PRIOR TO THE APPROVED PRICE INCREASE ACCEPTANCE DATE AT THE
ORIGINAL CONTRACT PRICE. APPROVAL OF ANY PRICE INCREASE RENEWS THE
FIRM PRICE PERIOD.

PRICE INCREASE REJECTION

WHEN THE STATE REJECTS A REQUEST FOR A PRICE INCREASE, THE CONTRACT
HOLDER WILL BE NOTIFIED IN WRITING OF THE STATE'S INTENTION PRIOR TO
THE FIRST OF THE FOLLOWING MONTH. IF THE CONTRACT IS TO BE CANCELED,
THE CONTRACT HOLDER WILL BE REQUIRED TO HONOR ALL PURCHASE ORDERS
THAT WERE PREPARED AND DATED PRIOR TO THE DATE OF THE TERMINATION,
IF RECEIVED BY THE CONTRACT HOLDER WITHIN A PERIOD OF THIRTY (30)
DAYS FOLLOWING THE DATE OF TERMINATION.
VENDOR REPORTING

CONTRACT VENDORS WILL BE REQUIRED TO SUBMIT REPORTS VALIDATING
CONTRACT PURCHASES, INCLUDING PURCHASES MADE BY LOCAL GOVERNMENTS, BY
PERIOD, LINE ITEM AND RECEIVING LOCATION. REPORTS WILL DETAIL AT A
MINIMUM, THE FOLLOWING INFORMATION:

1. CONTRACT NUMBER
2. CONTRACT LINE ITEM NUMBER
3. COMMODITY DESCRIPTION
4. LINE ITEM QUANTITY PURCHASED
5. LINE ITEM DOLLAR AMOUNT (VOLUME) PURCHASED

REPORTS ARE DUE AT THE PURCHASING DIVISION OFFICE IN APPROXIMATELY
THE FIRST WEEK OF THE FOURTH (4TH) QUARTER OF THE CONTRACT PERIOD
ANNUALLY.

REPORTS MUST BE SUBMITTED ELECTRONICALLY OR BY DIGITAL APPLIANCE IN
MICROSOFT EXCEL (.XLS) FORMAT. SEMI-ANNUAL OR QUARTERLY REPORTS MAY
BE REQUESTED IN WRITING BY THE CONTRACT ADMINISTRATOR WITH A THIRTY
(30) DAY WRITTEN NOTICE TO THE VENDOR.

STATE CONTRACT ADMINISTRATOR

QUESTIONS OR PROBLEMS ARISING FROM BID PROCEDURES OR SUBSEQUENT ORDER
AND DELIVERY PROCEDURES SHOULD BE DIRECTED TO:

STATE OF TENNESSEE
DEPARTMENT OF GENERAL SERVICES, PURCHASING DIVISION
312 ROSA L. PARKS AVENUE
3RD FLOOR WILLIAM R. SNODGRASS TN TOWER
NASHVILLE, TN 37243-0557

TO THE ATTENTION OF THE BUYER LISTED ON THE FACE OF THE
INVITATION TO BID.

PURCHASE ORDER RELEASE (SWC)

ORDERS FOR SERVICES OR SUPPLIES THAT ARE INCLUDED ON STATEWIDE
CONTRACTS SHALL BE PREPARED BY AGENCIES ON DEPARTMENTAL PURCHASE
ORDERS AND FORWARDED DIRECTLY TO THE VENDOR/CONTRACTOR. THESE PURCHASE
ORDERS, WHEN RECEIVED BY THE VENDOR/CONTRACTOR, SERVE AS AUTHORIZATION
FOR SHIPMENT. ITEMS FROM DIFFERENT CONTRACTS MAY BE COMBINED ON A
SINGLE PURCHASE ORDER TO THE SAME VENDOR/CONTRACTOR TO MEET MINIMUM
ORDER REQUIREMENTS. LOCAL GOVERNMENT AGENCIES OR AUTHORIZED
CORPORATIONS, WHERE APPLICABLE, WILL ISSUE THEIR PURCHASE ORDER
RELEASES DIRECTLY TO THE VENDOR/CONTRACTOR(S).

BILLING INSTRUCTIONS
THE CONTRACTOR SHALL INVOICE THE STATE ONLY AFTER COMPLETION OF THE
WORK DESCRIBED IN THE PURCHASE ORDER/CONTRACT, AND AS REQUIRED BELOW
PRIOR TO ANY PAYMENT.

THE CONTRACTOR SHALL SUBMIT AN INVOICE, WITH ALL NECESSARY SUPPORTING
DOCUMENTATION, TO: STATE AGENCY BILLING ADDRESS

SUCH INVOICE SHALL CLEARLY AND ACCURATELY DETAIL THE FOLLOWING
REQUIRED INFORMATION.

INVOICE/REFERENCE NUMBER; (ASSIGNED BY THE CONTRACTOR)
INVOICE DATE;
CONTRACT AND/OR PURCHASE ORDER NUMBER; (ASSIGNED BY THE STATE)
ACCOUNT NAME; PROCURING STATE AGENCY AND DIVISION NAME
ACCOUNT/CUSTOMER NUMBER; (UNIQUELY ASSIGNED BY THE CONTRACTOR TO
THE ABOVE-REFERENCED ACCOUNT NAME;
CONTRACTOR NAME;
CONTRACTOR FEDERAL EMPLOYER IDENTIFICATION NUMBER OR SOCIAL
SECURITY NUMBER; (AS REFERENCED IN CONTRACT)
CONTRACTOR CONTACT (NAME, PHONE, AND/OR FAX FOR THE INDIVIDUAL TO
CONTACT WITH BILLING QUESTIONS);
CONTRACTOR REMITTANCE ADDRESS;
DESCRIPTION OF DELIVERED ITEM OR SERVICE; AND
TOTAL AMOUNT DUE FOR DELIVERED ITEM OR SERVICE.

THE CONTRACTOR UNDERSTANDS AND AGREES THAT THE INVOICE SHALL;

INCLUDE ONLY CHARGES FOR SERVICE DESCRIBED IN CONTRACT OR PURCHASE
ORDER AND IN ACCORDANCE WITH PAYMENT TERMS AND CONDITIONS SET FORTH
IN CONTRACT OR PURCHASE ORDER;

NOT INCLUDE ANY FUTURE WORK BUT WILL ONLY BE SUBMITTED FOR
COMPLETED SERVICE; AND

NOT INCLUDE SALES TAX OR SHIPPING CHARGES (UNLESS OTHERWISE
STIPULATED IN THE CONTRACT OR PURCHASE ORDER).

THE CONTRACTOR AGREES THAT TIMEFRAME FOR PAYMENT (AND ANY DISCOUNTS)
BEGINS WHEN THE STATE IS IN RECEIPT OF A CORRECT INVOICE MEETING THE
MINIMUM REQUIREMENTS ABOVE.

PAYMENT

IT SHALL BE THE RESPONSIBILITY OF THE "BILL TO" AGENCY TO MAKE
PAYMENT. ANY QUESTIONS CONCERNING PAYMENT SHOULD BE ADDRESSED TO THE
"BILL TO" AGENCY LISTED IN THE TOP, RIGHT SIDE OF THE PURCHASE ORDER,
NOT THE PURCHASING DIVISION.

CANCELLATION

TERMINATION FOR CONVENIENCE: THE STATE MAY TERMINATE THIS CONTRACT
WITHOUT CAUSE. SAID TERMINATION SHALL NOT BE DEEMED A BREACH OF
CONTRACT BY THE STATE. THE STATE SHALL GIVE THE VENDOR/CONTRACTOR AT
LEAST NINETY (90) DAYS WRITTEN NOTICE BEFORE THE EFFECTIVE CANCELATION
DATE.
THE VENDOR/CONTRACTOR SHALL BE ENTITLED TO RECEIVE COMPENSATION FOR
GOODS SHIPPED OR SERVICES SATISFACTORILY COMPLETED AS OF THE
CANCELATION DATE, BUT IN NO EVENT SHALL THE STATE BE LIABLE TO THE
VENDOR/CONTRACTOR FOR COMPENSATION FOR ANY GOODS OR SERVICES WHICH
HAVE NOT BEEN RENDERED.
UPON SUCH TERMINATION, THE VENDOR/CONTRACTOR SHALL HAVE NO RIGHT TO
ANY ACTUAL GENERAL, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR ANY OTHER
CLAIMS WHATSOEVER OF ANY DESCRIPTION OR AMOUNT.

TERMINATION FOR CAUSE: IF THE VENDOR/CONTRACTOR FAILS TO FULFILL ITS
OBLIGATIONS UNDER THIS CONTRACT IN A TIMELY OR PROPER MANNER, OR IF
THE VENDOR/CONTRACTOR VIOLATES ANY TERMS OF THIS CONTRACT, THE STATE
SHALL HAVE THE RIGHT TO IMMEDIATELY TERMINATE THE CONTRACT UPON
WRITTEN NOTICE OF INTENT TO CANCEL. THE STATE SHALL HAVE THE RIGHT TO
WITHHOLD PAYMENT IN EXCESS OF FAIR COMPENSATION FOR COMPLETED
SERVICES. NOTWITHSTANDING THE ABOVE, THE CONTRACTOR SHALL NOT BE
RELIEVED OF LIABILITY TO THE STATE FOR DAMAGES SUSTAINED BY VIRTUE OF
ANY BREACH OF THIS CONTRACT BY THE CONTRACTOR.

AT THE END OF ANY FISCAL YEAR ANY CONTRACT MAY BE CANCELED BY THE
STATE WITHOUT NOTICE, IN THE EVENT THAT FUNDS TO SUPPORT THE CONTRACT
BECOME UNAVAILABLE.

THE VENDOR/CONTRACTOR WILL BE REQUIRED TO HONOR ALL PURCHASE ORDERS
THAT WERE PREPARED AND DATED PRIOR TO THE DATE OF THE TERMINATION, IF
RECEIVED BY THE VENDOR/CONTRACTOR WITHIN A PERIOD OF THIRTY (30) DAYS
FOLLOWING THE DATE OF TERMINATION.

SUBCONTRACTING: RESPONSIBILITIES AND LIABILITIES

THE CONTRACTOR SHALL NOT ENTER INTO ANY SUBCONTRACT FOR SERVICES
WITHOUT THE WRITTEN CONSENT OF THE DEPUTY COMMISSIONER, DEPARTMENT OF
GENERAL SERVICES, PURCHASING DIVISION. THE AWARDED CONTRACTOR IS
RESPONSIBLE FOR WORK, SERVICE, PERFORMANCE, CONTRACTUAL LIABILITY
WORKERS' COMPENSATION INJURIES OF EMPLOYEES AND SUBS (UNLESS
SUBCONTRACTOR ASSUMES RESPONSIBILITY AND FURNISHES AN ORIGINAL
CERTIFICATE OF INSURANCE AS PROOF OF INSURANCE FOR WORKERS'
COMPENSATION AND NAMING THE STATE OF TENNESSEE AS ADDITIONALLY INSURED
FOR GENERAL LIABILITY), AND PAYMENT TO THE SUBCONTRACTOR. ALL COSTS
INCURRED FOR SUBCONTRACTING MUST BE INCLUDED IN THE BID PRICE.

THE SUCCESSFUL BIDDER(S) WILL BE REQUIRED TO FURNISH A LABOR AND
MATERIAL SURETY BOND ISSUED BY A SURETY COMPANY LICENSED TO DO
BUSINESS IN THE STATE OF TENNESSEE IN THE AMOUNT OF TWENTY-FIVE (25) %
OF THE TOTAL CONTRACT AMOUNT. SUCH BOND SHALL BE FURNISHED TO THE
PURCHASING DIVISION WITHIN TEN (10) WORKING DAYS AFTER THE REQUEST.
THE SURETY BOND WILL INSURE THAT THE CONTRACTOR WILL PAY FOR ALL LABOR
AND MATERIALS USED BY THE CONTRACTOR, OR ANY IMMEDIATE OR REMOTE
SUBCONTRACTOR UNDER THE CONTRACTOR, IN SUCH CONTRACT, IN LAWFUL MONEY
OF THE UNITED STATES.


LIST BELOW THE NAME, COMPLETE ADDRESS AND PHONE NUMBER OF ALL
SUBCONTRACTOR(S):

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

SPECIFICATIONS FOR LINE ITEM 00001: V-BOX SPREADER, 1.8 CU. YD.

1) DIMENSIONS

A. BODY LENGTH - 8 FT.
(INSIDE)

B. WIDTH (INSIDE) - 50 INCHES

C. OVERALL LENGTH - 115.5 INCHES (MAX.)

D. HEIGHT - 34 INCHES (MAX.)

E. WEIGHT - 1,100 LBS. (MAX.)

2) BODY CAPACITIES

A. STRUCK - 1.75 CU. YD.

B. ROUNDED - 2.1 CU. YD.

3) BODY

A. GAUGE - SIDES 12 GAUGE, ENDS 14 GAUGE BOTH MFG. FROM GRADE 304
STAINLESS STEEL

B. TOP EDGE & SIDES - FORMED FOR STRENGTH WITH 40-45 DEGREES SIDE
SLOPES

C. SILLS - MFG. FROM GRADE 304 STAINLESS STEEL

D. FLOOR - 10 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL

E. LIFT POINT - LOCATED ON CROSS SUPPORT, SINGLE OR DUAL

F. HOLD DOWNS - NYLON STRAPS 1 INCH WIDTH, FOUR (4) EACH, WITH A
TENSILE STRENGTH OF 2,000 LBS EACH.

G. CROSS SUPPORTS - REQUIRED

4) CONVEYOR

A. SIZE - 16" OUTSIDE WIDTH W/MIN. .25" X 1" CROSS BARS SPACED ON
4.5" CENTERS

B. IDLER SHAFT - ADJUSTABLE

C. FEEDGATE - LEVER OPERATED, MFG. FROM GRADE 304 STAINLESS STEEL

D. CONVEYOR DRIVE - 20.1 REDUCTION

E. CONVEYOR PROTECTION - INVERTED "VEE" OVER CONVEYOR, MFG. FROM
GRADE 304 STAINLESS STEEL

5) SPINNER CHUTE ASSEMBLEY, 12 GAUGE, MFG. FROM GRADE 304 STAINLESS
STEEL

A. SPINNER - 13" DIAMETER, MFG. FROM GRADE 304 STAINLESS STEEL OR
POLYURETHANE

B. FINS - FOUR (4), MFG. FROM GRADE 304 STAINLESS STEEL OR
POLYURETHANE.

C. SHAFT MOUNTING - SHALL HAVE GREASE FITTINGS AT PIVOT POINTS

D. WIDTH OF SPREAD - 4' TO 30'

E. CONTROL OF DIRECTION - ADJUSTABLE REAR, LEFT & RIGHT

F. BAFFLES - ADJUSTABLE EXTERNALLY TO CONTROL SPREAD. INTERNAL TO
CONTROL MATERIAL FLOW TO SPINNER. MFG. FROM GRADE 304
STAINLESS STEEL.

G. TARP - HEAVY 16 OZ. NEOPRENE TREATED TARP, CUSTOM MADE FOR TIGHT
FIT. TARP TO BE FASTENED PERMANENTLY TO FRONT OF SPREADER
RUBBER ROPE OR TIE DOWNS POSITIONED ON THE OTHER THREE
SIDES.

H. HOPPER SCREENS - REQUIRED, 3/8" ROD SECTIONAL WITH 2.5 INCH
SQUARE OPENINGS

I. ENGINE - 11 HP HONDA, 4 CYCLE AIR COOLED, I/C GASOLINE, REAR
MOUNTED FULLY ENCLOSED ENGINE, HINGED HOOD.

J. MOTOR MFG. PLATE - 10 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL

K. CONTROLS - FULL IN CAB CONTROLS, ELECTRIC THROTTLE, STARTER
SWITCH, IGNITION & CLUTCH CONTROL. (NOTE: LENGTH OF
CONTROL CABLES MUST BE SUFFICIENT TO ACCOMODATE A
CREW CAB DUMP TRUCK)

L. ELECTRIC START - 12 VOLT W/BATTERY, ALTERNATOR & STARTER

M. HOURMETER - REQUIRED

N. CLUTCH - ELECTRIC W/CAB CONTROL SWITCH

O. UNIT ASSEMBLY - TO BE FULLY ASSEMBLED & READY FOR OPERATION

P. MANUALS - TO INCLUDE OPERATOR, PARTS, SERVICE, & SAFETY

6) WARRANTY

A. SPREADER - ONE (1) YEAR, 100% PARTS & LABOR

B. ENGINE - MANUFACTURER'S STANDARD ONE (1) YEAR SHALL APPLY

7) COLOR

A. CLEAN ENTIRE UNIT OF WELDING SLAG, OIL, RUST, ETC.

B. PHOSPHATE CLEAN

C. ONE (1) HEAVY COAT OF RUST INHIBITIVE PRIMER.

D. TWO (2) HEAVY COATS OF FINISH (SHERWIN WILLIAMS GENESIS BLACK
#GC-1738-A WITH GH1091 HARDENER LEAD FREE OR EQUAL.
OR
POWDER COAT WITH 5 STAGE WASH USING SAME FINISH AS ABOVE.
(NOTE: ANY COMPONENTS MADE OF 304 STAINLESS STEEL DO NOT
REQUIRE PAINT)

8) GENERAL

A. ALL STANDARD FEATURES TO BE FURNISHED AS ADVERTISED

9) DELIVERY

A. 120 DAYS MAXIMUM (BIDS FOR MORE THAN 120 DAYS WILL NOT BE
CONSIDERED FOR AWARD)


SPECIFICATIONS FOR LINE ITEM 00002: 15 GALLON POLYETHYLENE TANKS

TANKS ARE TRIANGULAR OR OBLONG IN CROSS SECTION AND ARE MADE TO MATE
WITH THE ANGLE OF THE V-BOX HOPPER. TO BE CONSTRUCTED OF ROTATIONALLY
MOLDED HIGH DENSITY, UV STABILIZED POLYETHYLENE. DESIGNED TO HOLD
MATERIAL WITH SPECIFIC GRAVITY OF UP TO 16 LBS/GAL. TANK FITTINGS ARE
POLYETHYLENE AND ARE ATTACHED USING A SPIN WELD PROCESS OR 0-RING
STYLE TANK ADAPTOR. TANK SHALL BE EQUIPPED WITH A 2" TOP FILL
OPENING LOCATED AT THE BACK OF THE TANK. A SINGLE QUICK CONNECTION
WITH VALVE IS ALSO INCLUDED FOR BOTTOM FILL, PROVIDING SAFETY AND
OPERATOR CONVENIENCE. WHEN DUAL TANKS ARE UTILIZED, THE TANKS ARE
TIED TOGETHER SO THAT SOLUTION IS WITHDRAWN FROM THE TANKS EVENLY
MAINTAINING PROPER WEIGHT DISTRIBUTION. ALL HOSES USED ARE NYLON
REINFORCED PVC FOR STRENGTH AND DURABILITY. ALL VALVE AND FITTINGS
ARE PVC/POLYPROPYLENE. EACH TANK HAS AN INLET VALVE TO ISOLATE FLOW.
ELECTRIC PUMP SYSTEM, VARIABLE CAB CONTROL WITH NOZZLES AND ALL
EQUIPMENT NECESSARY.
SPECIFICATIONS FOR LINE ITEM 00003: V-BOX SPREADER, 3 CU. YD.

1) DIMENSIONS

A. BODY LENGTH (INSIDE) - 8 FT.

B. WIDTH (INSIDE) - 70"

C. OVERALL LENGTH - 114"

D. HEIGHT - 38"

E. WEIGHT - 1,200 LBS. (MAX.)

2) BODY CAPACITIES

A. STRUCK - 3.0 CU. YD.

B. ROUNDED - 3.3 CU. YD.

3) BODY

A. GAUGES (SIDES, END, & - 12 GAUGE, MFG. FROM GRADE 304 STAINLESS
SIDE SPPORTS) STEEL

B. TOP EDGE & SIDES - CHANNEL FORMED, WITH APPROX. 45 DEGREE SIDE
SLOPE

C. SILLS - LONGSILLS SHALL BE 10 GAUGE 304 STAINLESS STEEL & SHALL
PROVIDE A FORMED OVER CHAIN SHIELD

D. FLOOR - 10 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL

E. LIFT POINTS - MFG. FROM GRADE 304 STAINLESS STEEL FOUR (4) LIFT
POINTS - ONE ON EACH CORNER

F. HOLD DOWNS - FOUR (4) RATCHET LOAD BINDERS
AND EYE BOLTS

4) CONVEYOR

A. SIZE - (APPROX.) 16.5" WIDE
.25" X 1" CROSS BARS ON EVERY OTHER LINK SPACING

B. IDLER SHAFT - 1" MIN. DIAMETER WITH 6-TOOTH, DROP FORGED STEEL
SPROCKETS & 3" MIN. ADJUSTMENT

C. FEED GATE - 12 GAUGE, (APPROX.) 4" X 12" MAX. OPENING, LEVER
OPERATED, MFG. FROM GRADE 304 STAINLESS STEEL

D. CONVEYOR DRIVE - 20:1 REDUCTION/1.125" DIAMETER DRIVE SHAFT WITH
6-TOOTH, DROP FORGED STEEL SPROCKETS

E. CONVEYOR PROTECTION - FORMED OVER CHAIN SHIELDS OR BOLT-IN
REPLACEABLE.

F. INVERTED V - 12 GAUGE, INVERTED "VEE" OVER CONVEYOR, MFG. FROM
GRADE 304 STAINLESS STEEL

5) SPINNER CHUTE ASSEMBLY - 12 GAUGE, MFG. FROM GRADE 304 STAINLESS
STEEL, EXTENDED SPINNER CHUTE FOR MOUNTING
ON FLATBED

A. SPINNER DISC - 13" DIAMETER, 12 GAUGE STAINLESS STEEL OR
POLYURETHANE.

B. FINS - POLYURETHANE OR 12 GUAGE MFG. FROM GRADE 304 STAINLESS
STEEL, 4 RADIAL FORMED FINS

C. SHAFT MOUNTING - 3/4" SPINNER SHAFT MOUNTED THROUGH 2 SELF-
ALIGNING, TRIPLE SEALED RELUBABLE PILLOW BLOCK
BEARINGS

D. WIDTH OF SPREAD - (APPROX.) 4' TO 35'

E. CONTROL OF DIRECTION - ADJUSTABLE SPREAD PATTERN TO LEFT, RIGHT
& REAR OF UNIT

F. BAFFLES - 3 EXTERNAL ADJUSTABLE BAFFLES TO CONTROL SPREAD

G. HOPPER SCREENS - HEAVY-DUTY SCREEN CONSTRUCTED OF APPROX. 3/8"
ROD FORMING 2 1/2" SQUARE OPENINGS

H. ENGINE - 11 HP HONDA, 4 CYCLE ENGINE WITH CAST IRON CYLINDER
SLEEVE, PRESSURE LUBRICATION & DUAL AIR FILTRATION
SYSTEM. HINGED HOOD ASSEMBLY TO PROTECT ENGINE FROM
THE ELEMENTS.

I. CONTROL PANEL - CAB MOUNTED CONTROL PANEL WITH HOURMETER.
CONTROL PANEL OPERATES ENGINE START, STOP,
ELECTRIC THROTTLE, ELECTRIC CHOKE & CLUTCH.
(NOTE: LENGTH OF CABLE MUST BE SUFFICIENT TO
ACCOMMODATE A CREW CAB DUMP TRUCK)

J. TARP - HEAVY 16 OZ. NEOPRENE TREATED TARP, CUSTOM MADE FOR
TIGHT FIT. TARP TO BE FASTENED PERMANENTLY TO FRONT OF
SPREADER. RUBBER ROPE OR TIE DOWNS POSITIONED ON THE
OTHER THREE SIDES.

K. ELECTRIC START - REQUIRED

L. BATTERY - 12 VOLT

M. HOURMETER - REQUIRED

N. CLUTCH - ELECTRIC CLUTCH WITH CAB MOUNTED CONTROL SWITCH

O. UNIT ASSEMBLY - TO BE FULLY ASSEMBLY & READY FOR OPERATION

P. MANUALS - TO INCLUDE OPERATOR'S, PARTS, SERVICE & SAFETY

6) WARRANTY

A. SPREADER - ONE (1) YEAR, 100% PARTS & LABOR

B. ENGINE - MANUFACTURER'S STANDARD 1 YEAR SHALL APPLY

7) COLOR

A. CLEAN ENTIRE UNIT OF WELDING SLAG, OIL, RUST, ETC.

B. PHOSPHATE CLEAN

C. ONE (1) HEAVY COAT OF RUST INHIBITIVE PRIMER

D. TWO (2) HEAVY COATS FINISH, SHERMAN WILLIAMS GENESIS BLACK
#GC-1738-A WITH GH1091 HARDENER LEAD FREE OR EQUAL.
OR
POWER COAT WITH 5 STAGE WASH USING SAME FINISH AS ABOVE.
(NOTE: ANY COMPONENTS MFG. FROM GRADE 304 STAINLESS STEEL DO
NOT REQUIRE PAINT)

8) GENERAL - ALL STANDARD FEATURES TO BE FURNISHED AS ADVERTISED

A. ALL STANDARD FEATURES TO BE FURNISHED AS ADVERTISED

9) DELIVERY

A. 120 DAYS MAXIMUM (BIDS FOR OVER 120 DAYS WILL NOT BE CONSIDERED
FOR AWARD)


SPECIFICATIONS FOR LINE ITEM 00004: 30 GALLON POLYETHYLENE TANKS

SAME SPECIFICATIONS AS LINE ITEM 2

SPECIFICATIONS FOR LINE ITEM 00005: V-BOX SPREADER, 5 CU. YD.

1) DIMENSIONS

A. BODY LENGTH (INSIDE) - 9.0 FT. (SLOPED FRONT FOR HOIST WELL)

B. WIDTH (INSIDE) - 80"

C. OVERALL LENGTH - 125"

D. HEIGHT - 50"

E. WEIGHT - 1,840 LBS.

2) BODY CAPACITIES

A. STRUCK - 4.88 CU. YD.

B. ROUNDED - 5.4 CU. YD.

3) BODY

A. GAUGES (SIDES, END & - 10 GAUGE, MFG. FROM GRADE 304 STAINLESS
SIDE SUPPORTS) STEEL

B. TOP EDGES & SIDES - (APPROX.) 2 1/4" X 1 1/8" CHANNEL FORMED
TOP WITH APPROX. 40 TO 45 DEGREE SIDE SLOPES

C. SILLS - 10 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL

D. FLOOR - 7 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL

E. LIFT POINTS - FOUR (4) APPROX. 3/4" LIFTING LOOPS, 1 AT EACH
CORNER

F. HOLD DOWNS - FOUR (4) RATCHET LOAD BINDER HOLD DOWN CLAMPS WITH
TAILGATE LATCHING DEVICE

4) CONVEYOR

A. SIZE - (APPROX.) 24" WIDE CONVEYOR WITH 3/8" X 1 1/2" X 18 3/4"
CROSSBARS WELDED BOTH TOP/BOTTOM TO EVERY OTHER CHAIN
LINK.

B. CHAIN - HEAT-TREATED, 2 1/4" PITCH, SELF-CLEANING PINTLE CHAIN
WITH 7/16" LOCKED NON-TURNING PINS

C. IDLER SHAFT - 1 1/2" MINIMUM C-1045 IDLER SHAFT WITH MINIMUM
4" OF ADJUSTMENT

D. IDLER SPROCKETS - 8-TOOTH DROP FORGED SPROCKETS

E. GREASE EXTENSIONS - IDLER GREASE EXTENSIONS TO REAR OF UNIT
ARE REQUIRED.

F. FEED GATE - (APPROX.) 12" X 18", MFG. FROM GRADE 304 STAINLESS
STEEL. TO BE ADJUSTED WITH THE USE OF A SCREW TYPE
FEEDGATE JACK ASSEMBLY WITH CURB SIDE HANDLE.

G. CONVEYOR DRIVE - 50:1 REDUCTION

H. DRIVE SHAFT - 1 1/2" MINIMUM C-1045 DRIVE SHAFT

I. DRIVE SPROCKETS - 8-TOOTH DROP FORGED SPROCKETS

J. CONVEYOR PROTECTION - LONGITUDINAL SILLS SHALL BE "FORMED OVER"
TO PROTECT CONVEYOR CHAINS STRANDS.

K. INVERTED V - INVERTED "VEE" OVER CONVEYOR, MFG. FROM GRADE 304
STAINLESS STEEL.

5) SPINNER CHUTE ASSEMBLY - HOPPER CONSTRUCTION SHALL BE 12 GAUGE,
MFG. FROM GRADE 304 STAINLESS STEEL.
CHUTE TO BE VERTICALLY ADJUSTABLE 12"

A. SPINNER DISC - 18" DIAMETER, 7 GAUGE STAINLESS STEEL SPINNER
DISC.

B. FINS - 304 STAINLESS STEEL, 6 EACH, REPLACEABLE FINS

C. HYDRAULIC MOTOR - MOTOR TO BE DIRECT COUPLED TO SPINNER DISC
THROUGH REPLACEABLE HUB, WITH THE MOTOR
MOUNTED ABOVE THE DISC AND OUTSIDE THE
MATERIAL FLOW.

D. REAR DEFLECTOR PANEL - SPINNER CHUTE SHALL CONTAIN A REAR
DEFLECTOR PANEL, WHICH WILL ALLOW
MATERIAL TO BE DISCHARGED WITHOUT RUNNING
OVER THE SPINNER DISC.

E. SWING UP CHUTE - ENTIRE SPINNER SHALL SWING UP TO ALLOW UNIT
CLEANING, UNLOADING AND STORAGE.

F. WIDTH OF SPREAD - APPROX. 4' TO 40'

G. BAFFLES - FOUR (4) EXTERNAL BAFFLES, FRONT TO BE FIXED, SIDES
AND REAR TO BE ADJUSTABLE WITHOUT THE USE OF TOOLS.

H. HOPPER SCREENS - SCREENS SECTIONS ARE TO HAVE APPROX. 3/8" ROD
WELDED TO 1/4" X 2" ANGLE FORMING, APPROX.
2 3/8" X 2 1/2" OPENINGS. SCREENS SHALL BE
HINGED TO APPROX. 6" X 9 LB. STAINLESS STEEL
I-BEAM OR STAINLESS STEEL BOX BEAM OR STAINLESS
STEEL RECTANGULAR TUBING RUNNING THE LENGTH
OF THE BODY. AT THE OUTER EDGE, SCREENS
SHALL NEST INTO THE BODY TO PREVENT MOVEMENT OR
MANUFACTURER'S DESIGN FOR TOP MOUNTING HINGE TO
PREVENT MOVEMENT.

6) POWER DRIVE

A. TO BE HYDRAULIC, HAVING 2 HYDRAULIC MOTORS, 1 FOR SPINNER &
1 FOR CONVEYOR.

7) HOSES

A. VENDOR TO SUPPLY FOUR (4) HYDRAULIC HOSES TOTAL (2 FOR THE
SPINNER SUPPLY/RETURN AND 2 FOR THE CONVEYOR SUPPLY/RETURN.
HOSES SHALL BE OF SUFFICIENT LENGTH TO CONNECT TO HYDRAULIC
TERMINALS LOCATED BETWEEN FRAME RAILS AT REAR OF TRUCK.

8) UNIT ASSEMBLY

A. UNIT IS TO BE FULLY ASSEMBLED AND READY TO OPERATE AFTER
CONNECTING HYDRAULIC HOSES TO TRUCK.

9) MANUALS

A. TO INCLUDE OPERATOR'S, PARTS, SERVICE & SAFETY

10) WARRANTY

A. ONE (1) YEAR 100% PARTS & LABOR

11) COLOR

A. CLEAN ENTIRE UNIT OF WELDING SLAG, OIL, RUST, ETC.

B. PHOSPATE CLEAN

C. ONE (1) HEAVY COAT OF RUST INHIBITIVE PRIMER

D. TWO (2) HEAVY COATS FINISH, SHERWIN WILLIAMS GENESIS BLACK
#GC-1738-A WITH GH1091 HARDENER LEAD FREE OR EQUAL.
OR

POWER COAT WITH 5 STAGE WASH USING SAME FINISH AS ABOVE.
(NOTE: ANY COMPONENTS MFG. FROM GRADE 304 STAINLESS STEEL
DO NOT REQUIRE PAINT)

12) STANDARD EQUIPMENT

A. REQUIRED AS ADVERTISED IN MFG'S PRINTED LITERATURE

13) DELIVERY

A. 120 DAYS MAXIMUM (BIDS FOR OVER 120 DAYS WILL NOT BE CONSIDERED
FOR AWARD)


SPECIFICATIONS FOR LINE ITEM 00006: 75 GALLON POLYETHYLENE TANKS WITH
MOLDED BAFFLES

SAME SPECIFICATIONS AS LINES 2 & 4

SPECIFICATIONS FOR LINE ITEM 00007: V-BOX SPREADER, 9 CU. YD.

1) DIMENSIONS

A. BODY LENGTH (INSIDE) - 13 FT. (SLOPED FRONT FOR HOIST WELL)

B. WIDTH (INSIDE) - 80"

C. OVERALL LENGTH - 174"

D. HEIGHT - 56"

E. WEIGHT - 2,400 LBS.

2) BODY CAPACITIES

A. STRUCK - 8.59 CU. YD.

B. ROUNDED - 9.0 CU. YD.

3) BODY

A. GAUGE (SIDES, END & - 10 GAUGE, MFG. FROM GRADE 304 STAINLESS
SIDE SUPPORTS) STEEL.

B. TOP EDGE & SIDES - (APPROX.) 2 1/4" X 1 1/8" CHANNEL FORMED
TOP. 40-45 DEGREE SIDE SLOPE.

C. SILLS - 10 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL.

D. FLOOR - 7 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL.

E. LIFT POINTS - FOUR (4) 3/4" LIFTING LOOPS, 1 AT EACH CORNER

F. HOLD DOWNS - FOUR (4) RATCHET LOAD BINDER HOLD DOWN CLAMPS WITH
TAILGATE LATCHING DEVICE.

4) CONVEYOR

A. SIZE - 24" WIDE WITH 3/8" X 1 1/2" X 18 3/4" CROSSBARS WELDED
BOTH TOP/BOTTOM TO EVERY OTHER CHAIN LINK.

B. CHAIN - HEAT-TREATED, 2 1/4" PITCH, SELF-CLEANING PINTLE CHAIN
WITH 7/16" LOCKED NON-TURNING PINS.

C. IDLER SHAFT - 1 1/2" MINIMUM C-1045 IDLER SHAFT WITH MINIMUM
4" OF ADJUSTMENT.

D. IDLER SPROCKETS - 8-TOOTH DROP FORGED SPROCKETS

E. GREASE EXTENSIONS - IDLER GREASE EXTENSIONS TO REAR OF UNIT
ARE REQUIRED.

F. FEED GATE - (APPROX.) 12" X 18" FEED GATE TO BE ADJUSTED WITH
THE USE OF A SCREW TYPE FEED GATE JACK ASSEMBLY
WITH CURB SIDE HANDLE. MFG. FROM GRADE 304 STAINLESS
STEEL.

G. CONVEYOR DRIVE - 50:1 REDUCTION

H. DRIVE SHAFT - 1 1/2" MINIMUM C-1045 DRIVE SHAFT

I. DRIVE SPROCKETS - 8-TOOTH DROP FORGED SPROCKETS

J. CONVEYOR PROTECTION - LONGITUDINAL SILLS SHALL BE "FORMED OVER"
TO PROTECT CONVEYOR CHAIN STRANDS.

K. INVERTED V - INVERTED "VEE" OVER CONVEYOR, MFG. FROM GRADE 304
STAINLESS STEEL.

5) SPINNER CHUTE ASSEMBLY - CHUTE CONSTRUCTION SHALL BE 12 GAUGE,
MFG. FROM GRADE 304 STAINLESS STEEL. CHUTE
TO BE VERTICALLY ADJUSTABLE 12"

A. SPINNER DISC - 18" DIAMETER, 7 GAUGE STAINLESS STEEL SPINNER
DISC.

B. FINS - SIX (6), 10 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL
REPLACEABLE FINS.

C. HYDRAULIC MOTOR - MOTOR TO BE DIRECT COUPLED TO SPINNER DISC
THROUGH REPLACEABLE HUB, WITH THE MOTOR
MOUNTED ABOVE THE DISC AND OUTSIDE THE
MATERIAL FLOW.

D. REAR DEFLECTOR PANEL - SPINNER CHUTE SHALL CONTAIN A REAR
DEFLECTOR PANEL, WHICH WILL ALLOW
MATERIAL TO BE DISCHARGED WITHOUT
RUNNING OVER THE SPINNER DISC.

E. SWING UP CHUTE - ENTIRE SPINNER SHALL SWING UP TO ALLOW
UNIT CLEANING, UNLOADING AND STORAGE.

F. WIDTH OF SPREAD - (APPROX.) 4' TO 30'

G. BAFFLES - FOUR (4) EXTERNAL BAFFLES, FRONT TO BE FIXED, SIDES
AND REAR TO BE ADJUSTABLE WITHOUT THE USE OF TOOLS.

H. CONTROL OF DIRECTION - INTERNAL/EXTERNAL BAFFLES

I. HOPPER SCREENS - SCREEN SECTIONS ARE TO HAVE APPROX. 3/8" ROD
WELDED TO 1/4" X 2" ANGLE FORMING APPROX. 2 3/8
X 2 1/2" OPENINGS. SCREENS SHALL BE HINGED TO A
6" X 9 LB. STAINLESS STEEL I-BEAM OR 304
STAINLESS STEEL BOX BEAM RUNNING THE LENGTH OF
THE BODY. AT THE OUTER EDGE, SCREENS SHALL NEST
INTO THE BODY TOPREVENT MOVEMENT OR
MANUFACTURER'S DESIGN FOR TOP MOUNTING TO
PREVENT MOVEMENT.

6) POWER DRIVE

A. TO BE HYDRAULIC, HAVING 2 HYDRAULIC MOTORS, 1 FOR SPINNER &
1 FOR CONVEYOR.

7) HOSES

A. VENDOR TO SUPPLY FOUR (4) HYDRAULIC HOSES TOTAL, 2 FOR THE
SPINNER SUPPLY/RETURN AND 2 FOR THE CONVEYOR SUPPLY/RETURN.
HOSES SHALL BE OF SUFFICIENT LENGTH TO CONNECT TO HYDRAULIC
TERMINALS LOCATED BETWEEN FRAME RAILS AT REAR OF TRUCK.

8) UNIT ASSEMBLY

A. UNIT IS TO BE FULLY ASSEMBLED AND READY TO OPERATE AFTER
CONNECTING HYDRAULIC HOSES TO TRUCK.

9) MANUALS

A. TO INCLUDE OPERATOR'S, PARTS, SERVICE & SAFETY

10) WARRANTY

A. ONE (1) YEAR, 100% PARTS & LABOR

11) COLOR

A. CLEAN ENTIRE UNIT OF WELDING SLAG, OIL, RUST, ETC.

B. PHOSPHATE CLEAN

C. ONE (1) HEAVY COAT OF RUST INHIBITIVE PRIMER

D. TWO (2) HEAVY COATS FINISH, SHERWIN WILLIAMS GENESIS BLACK
#GC-1738-A WITH GH1091 HARDENER LEAD FREE OR EQUAL.
OR
POWDER COAT WITH 5 STAGE WASH USING SAME FINISH AS ABOVE
(NOTE: ANY COMPONENTS MADE FROM GRADE 304 STAINLESS STEEL
DO NOT REQUIRE PAINT)

12) STANDARD EQUIPMENT

A. REQUIRED AS ADVERTISED IN MFG'S PRINTED LITERATURE


SPECIFICATIONS FOR LINE ITEM 00009: 90 GALLON POLYETHYLENE TANKS
WITH MOLDED BAFFLES

SAME SPECIFICATIONS AS LINES 2, 4 AND 6

SPECIFICATIONS FOR LINE ITEM 00008: V-BOX SPREADER, 10 CU. YD.

1) DIMENSIONS

A. BODY LENGTH (INSIDE) - 16 FT. (SLOPED FRONT FOR HOIST WELL)

B. WIDTH (INSIDE) - 82"

C. OVERALL LENGTH - 216"

D. HEIGHT - 50"

E. WEIGHT - 2,800 LBS.

2) BODY CAPACITIES

A. STRUCK - 10 CU. YD.

B. ROUNDED - 11 CU. YD.

3) BODY

A. GAUGE (SIDES, END & - 10 GAUGE, MFG. FROM GRADE 304 STAINLESS
SIDE SUPPORTS) STEEL.

B. TOP EDGE & SIDES - (APPROX.) 2 1/4" X 1 1/8" CHANNEL FORMED TOP,
40-45 DEGREE SIDE SLOPE.

C. SILLS - 10 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL

D. FLOOR - 7 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL

E. LIFT POINTS - FOUR (4) 3/4" LIFTING LOOPS, 1 AT EACH CORNER

F. HOLD DOWNS - FOUR (4) RATCHET LOAD BINDER HOLD DOWN CLAMPS WITH
TAILGATE LATCHING DEVICE.

4) CONVEYOR

A. SIZE - (APPROX.) 24" WIDE CONVEYOR WITH 1/4" X 1 1/2" X 18 3/4"
CROSSBARS WELDED BOTH TOP/BOTTOM TO EVERY OTHER CHAIN
LINK.

B. CHAIN - HEAT-TREATED, 2 1/4" PITCH, SELF-CLEANING PINTLE CHAIN
WITH 7/16" LOCKED NON-TURNING PINS.

C. IDLER SHAFT - 1 1/2" MINIMUM C-1045 IDLER SHAFT WITH MINIMUM
4" OF ADJUSTMENT.

D. IDLER SPROCKETS - 8-TOOTH DROP FORGED SPROCKETS

E. GREASE EXTENSIONS - IDLER GREASE EXTENSIONS TO REAR OF UNIT ARE
REQUIRED.

F. FEED GATE - (APPROX.) 12" X 18", MFG. FROM GRADE 304 STAINLESS
STEEL, TO BE ADJUSTED WITH THE USE OF A SCREW TYPE
FEED GATE JACK ASSEMBLY WITH CURB SIDE HANDLE.

G. CONVEYOR DRIVE - 50:1 REDUCTION

H. DRIVE SHAFT - 1 1/2" MINIMUM C-1045 DRIVE SHAFT

I. DRIVE SPROCKETS - 8-TOOTH DROP FORGED SPROCKETS

J. CONVEYOR PROTECTION - LONGITUDINAL SILLS SHALL BE "FORMED OVER"
TO PROTECT CONVEYOR CHAIN STRANDS.

K. INVERTED V - INVERTED "VEE" OVER CONVEYOR, MFG. FROM GRADE 304
STAINLESS STEEL.

5) SPINNER CHUTE ASSEMBLY - HOPPER CONSTRUCTION SHALL BE 12 GAUGE,
MFG. FROM GRADE 304 STAINLESS STEEL. CHUTE
TO BE VERTICALLY ADJUSTABLE 12"

A. SPINNER DISC - 18" DIAMETER, 7 GAUGE STAINLESS STEEL SPINNER
DISC.

B. FINS - SIX (6), 10 GAUGE, MFG. FROM GRADE 304 STAINLESS STEEL

C. HYDRAULIC MOTOR - MOTOR TO BE DIRECT COUPLED TO SPINNER DISC
THROUGH REPLACEABLE HUB, WITH THE MOTOR
MOUNTED ABOVE THE DISC AND OUTSIDE THE
MATERIAL FLOW.

D. REAR DEFLECTOR PANEL - SPINNER CHUTE SHALL CONTAIN A REAR
DEFLECTOR PANEL, WHICH WILL ALLOW
MATERIAL TO BE DISCHARGED WITHOUT
RUNNING OVER THE SPINNER DISC.

E. SWING UP CHUTE - ENTIRE SPINNER SHALL SWING UP TO ALLOW UNIT
CLEANING, UNLOADING AND STORAGE.

F. WIDTH OF SPREAD - (APPROX.) 4' TO 40'

G. BAFFLES - FOUR (4) EXTERNAL BAFFLES, FRONT TO BE FIXED, SIDES
AND REAR TO BE ADJUSTABLE WITHOUT USE OF TOOLS.

H. CONTROL OF DIRECTION - INTERNAL/EXTERNAL BAFFLES

I. HOPPER SCREENS - SCREEN SECTIONS ARE TO HAVE APPROX. 3/8" ROD
WELDED TO 1/4" X 2" ANGLE FORMING APPROX. 2 3/8
X 2 1/2" OPENINGS. SCREENS SHALL BE HINGED TO A
6" X 9 LB. STAINLESS STEEL I-BEAM OR 304
STAINLESS STEEL BOX BEAM RUNNING THE LENGTH
OF THE BODY. AT THE OUTER EDGE, SCREENS SHALL
NEST INTO THE BODY TOPREVENT MOVEMENT OR
MANUFACTURER'S DESIGN FOR TOP MOUNTING TO
PREVENT MOVEMENT.

6) POWER DRIVE

A. TO BE HYDRAULIC, HAVING 2 HYDRAULIC MOTORS, 1 FOR SPINNER &
1 FOR CONVEYOR.

7) HOSES - VENDOR TO SUPPLY FOUR (4) HYDRAULIC HOSES TOTAL, 2 FOR THE
SPINNER SUPPLY/RETURN AND 2 FOR THE CONVEYOR SUPPLY/RETURN.
HOSES SHALL BE OF SUFFICIENT LENGTH TO CONNECT TO HYDRAULIC
TERMINALS LOCATED BETWEEN FRAME RAILS AT REAR OF TRUCK.

8) UNIT ASSEMBLY - UNIT TO BE FULLY ASSEMBLE AND READY TO OPERATE
AFTER CONNECTING HYDRAULIC HOSES TO TRUCK.

9) MANUALS - TO INCLUDE OPERATOR'S, PARTS, SERVICE & SAFETY

10) WARRANTY - ONE (1) YEAR, 100% PARTS AND LABOR

11) COLOR

A. CLEAN ENTIRE UNIT OF WELDING SLAG, OIL, RUST, ETC.

B. PHOSPHATE CLEAN

C. ONE (1) HEAVY COAT OF RUST INHIBITIVE PRIMER.

D. TWO (2) HEAVY COATS FINISH, SHERWIN WILLIAMS GENESIS BLACK
#GC-1738-A WITH GH1091 HARDENER LEAD FREE OR EQUAL.
OR
POWDER COAT WITH 5 STAGE WASH USING SAME FINISH AS ABOVE.
(NOTE: ANY COMPONENTS MFG. FROM GRADE 304 STAINLESS STEEL
DO NOT REQUIRE PAINT)

12) STANDARD EQUIPMENT - REQUIRED AS ADVERTISED IN MFG'S PRINTED
LITERATURE.


SPECIFICATIONS FOR LINE ITEM 00011: 90 GALLON POLYETHLENE TANK

SAME SPECIFICATIONS AS LINES 2, 4, 6 & 8

SPECIFICATIONS FOR LINE ITEM 00010: APPLICATOR W/GROUND SPEED CONTROL
(200 GALLON)

DESCRIPTION

DIRECT APPLICATION SYSTEM DESIGNED TO APPLY LIQUID ANTI-ICERS AND
DEICERS DIRECTLY TO THE ROAD SURFACE FROM THE MINIMUM 200 GALLON
FRAME MOUNT TANK IN PICKUP TRUCK. SPRAY NOZZLES ARE STRAIGHT STREAM
AND WILL COVER 8' TO 12' WIDE. SYSTEM IS A SLIDE IN TYPE FOR EASY
LOAD AND UNLOAD WITH A FORKLIFT.

TANK

MOLDED POLYETHYLENE TANK HAS A CAPACITY OF 200 GALLONS (MINIMUM) AND
IS RATED FOR MATERIALS UP TO 16 LBS. PER GALLON. IT IS ROTATIONALLY
MOLDED OF HIGH IMPACT LINEAR POLYETHYLENE WITH UV STABILIZERS. IT HAS
A 8" VENTED LID AND A 2" NPT OUTLET. TWO (2) GALVANIZED STEED
BANDS ATTACH THE TANK TO THE FRAME.
NOTE: TANK MUST HAVE A SLOPED BOTTOM FOR TOTAL DRAINAGE.

TANK FRAME

THE TANK FRAME IS FABRICATED STEEL, HOT DIP GALVANIZED OR STAINLESS
STEEL FOR CORRISION PROTECTION. IT HOLDS THE TANK, PUMP UNIT AND
PLUMBING. IT IS FORMED TO ALLOW FOR ACCESS BY FORKLIFT FOR EASY
LOADING AND UNLOADING.

PUMP UNIT

THE PUMP UNIT SHALL BE A HYPRO 1537 INCLUDING HYPRO 9203C CENTRIFUGAL
PUMP CLOSE-COUPLED TO A HONDA 5.5 HP ENGINE. THE PUMP SHALL BE RATED
TO DELIVER 88 GPM AT 40 PSI AND 30 GPM AND 70 PSI. 2" DRAIN/FILL VALVE
WITH 2" MALE ADAPTOR & CAP REAR MOUNTED. GLASS-FILLED NYLON IMPELER.
CAST IRON HOUSING

SPRAY BAR

THREE (3) LANE COVERAGE - THE CENTER LANE BAR SHALL BE CONSTRUCTED
FROM 1" STAINLESS STEEL SCHEDULE 40 PIPE AND CONTAIN TEN (10) BRASS
STRAIGHT STREAM QUICK-CHANGE NOZZLES MOUNTED IN A 16 DEGREE SWIVEL
MOUNT, WHICH CLIPS ONTO SPRAY BAR, OFFERING QUICK CHANGE CAPABILITIES.
THE SIDE LANES ARE TO BE A BOOMLESS TYPE NOZZLE THAT MOUNTS ON THE
ENDS OF THE CENTER BAR. IT IS ATTACHED TO A GALVANIZED STEEL SUPPORT
DESIGNED FOR MOUNTING IN A 2" X 2" TRAILER HITCH RECEIVER.
HOSE FROM THE PUMP TO THE SPRAY BAR IS 1" DIAMETER
AND CONTAINS A PRESSURE CHECK VALVE TO PREVENT SIPHONING FROM THE
TANK WHEN THE PUMP IS OFF. LANE COVERAGE CAN BE ADJUSTED FROM 8' TO
12' WIDE. THE SPRAY BARS ARE INDIVIDUALLY CONTROLLED BY THE OPERATOR
FROM THE CAB WITH THREE ELECTRIC ACTUATED POLY BALL VALVES.

PLUMBING

TANK VALVE - 2" POLYPROPYLENE
3 BANK ELECTRIC VALVES - 1" OUTLET TO SPRAY BAR, 12 V DC POWER,
PLUNGE STYLE VALVE, POLY HOUSING
BY-PASS CONTROL - 2 EACH, 1" POLY BALL VALVES FOR MANUAL CONTROL
RECIRCULATION/BYPASS LINE - 1" RUBBER RETURN TO TANK WITH POLY
BULKHEAD
LINE STRAINER - 2" POLYPROPYLENE WITH 80 MESH STAINLESS STEEL SCREEN
FITTINGS - POLYPROPYLENE OR PVC SHC 80
HOSE CLAMPS - STAINLESS STEEL

CAB CONTROL

GROUND SPEED CONTROLLER MUST CONTROL BOTH ANTI-ICING AND HERBICIDE
APPLICATION.

HOSE REEL

MANUAL HOSE REEL WITH 50' OF 1" HIGH PRESSURE HOSE WITH 17" ADJUSTABLE
SPRAY NOZZLE. (HYPRO MODEL 3381 OR EQUAL)

REQUIRED HERBICIDE CONVERSION

UNIT TO HAVE 3 NOZZLE STREAM TO SPRAY THREE (3) APPLICATIONS:
(1) WIDTH BESIDE ROADWAY; (2) GUARDRAIL; (3) DITCH BANK.
NOTE: THREE (3) MANUAL CHANGE OVER VALVES REQUIRED TO SWITCH FROM
SUMMER TO WINTER APPLICATIONS.

GROUND SPEED CONTROL SYSTEM COMPATIBLE WITH AND DESIGNED TO BE USED
WITH CALCIUM CHLORIDE OR SALT BRINE APPLICATOR AS DECRIBED IN THE
ABOVE SPECIFICATIONS. MUST BE CAPABLE OF SENSING GROUND SPEED AND
CONTROLLING SPREAD RATE PROPORTIONATELY RANGING FROM MAXIMUM SPREAD
RATE DOWN TO ZERO DEPENDING ON WHETHER THE TRUCK IS MOVING OR STOPPED.
RADAR OR GPS SYSTEM WILL BE ACCEPTABLE.
HERBICIDE CONVERSION TO MOUNT IN RECEIVER HITCH OF TRUCK, EASILY
CONVERTABLE WITHOUT TOOLS AND MUST BE ABLE TO BE STOWED WHEN NOT IN
USE.

MEASUREMENT CAPABILITIES:

1) GALLONS PER ACRE
2) GALLONS PER MINUTE
3) TOTAL GALLONS
4) TOTAL ACRE
5) SUB ACRES
6) AREA PER HOUR
7) GROUND SPEED
8) TOTAL ACRES SPRAYED

SYSTEM FEATURES TO BE INCLUDED: PUSH-BUTTON CONTROLS, OUT-OF-RANGE
WARNING LIGHT, STATUS INDICATORS, PANEL LIGHTING, WEATHER RESISTANT
CONSOLE AND WEATHERPROOF CABLE CONNECTORS.


SPECIFICATIONS FOR LINE ITEM 00012: APPLICATOR W/GROUND SPEED CONTROL
(500 GALLON)

DESCRIPTION

DIRECT APPLICATION SYSTEM IS DESIGNED TO APPLY LIQUID ANTI-ICERS AND
DEICERS DIRECTLY TO THE ROAD SURFACE FROM A 500 GALLON FRAME MOUNT
TANK IN A FLATBED TRUCK. SPRAY NOZZLES ARE STRAIGHT STREAM AND WILL
COVER 8' TO 12' WIDE. THE SYSTEM IS A SLIDE IN TYPE FOR EASY LOAD AND
UNLOAD WITH A FORKLIFT.

TANK

MOLDED POLYETHELANE TANK HAS A CAPACITY OF 500 GALLONS AND IS RATED
FOR MATERIALS UP TO 16 LBS. PER GALLON. IT IS ROTATIONALLY MOLDED OF
HIGH IMPACT LINEAR POLYETHYLENE WITH UV STABILIZERS. IT HAS A 8"
VENTED LID AND A 2" NPT OUTLET. TWO (2) GALVANIZED STEED BANDS ATTACH
THE TANK TO THE FRAME. TANK MUST HAVE SLOPED BOTTOM FOR TOTAL DRAINAGE

TANK FRAME

THE TANK FRAME IS FABRICATED STEEL, HOT DIP GALVANIZED OR STAINLESS
STEEL FOR CORRISION PROTECTION. IT HOLDS THE TANK, PUMP UNIT, AND
PLUMBING. IT IS FORMED TO ALLOW FOR ACCESS BY FORKLIFT FOR EASY
LOADING AND UNLOADING.

PUMP UNIT

THE PUMP UNIT SHALL BE A HYPRO 1537 INCLUDING HYPRO 9203C CENTRIFUGAL
PUMP CLOSE-COUPLED TO A HONDA 5.5 HP ENGINE. THE PUMP SHALL BE RATED
TO DELIVER 88 GPM AT 40 PSI AND 30 GPM AT 70 PSI. 2' DRAIN/FILL VALVE
WITH 2" MALE ADAPTOR & CAP REAR MOUNTED. GLASS-FILLED NYLON IMPELER.
CAST IRON HOUSING.

SPRAY BAR

THREE (3) LANE COVERAGE - THE CENTER LANE BAR SHALL BE CONSTRUCTED
FROM 1" STAINLESS STEEL SCHEDULE 40 PIPE AND CONTAIN TEN (10) BRASS
STRAIGHT STREAM QUICK-CHANGE NOZZLES MOUNTED IN A 16 DEGREE SWIVEL
MOUNT, WHICH CLIPS ONTO SPRAY BAR, OFFERING QUICK-CHANGE CAPABILITIES.
THE SIDE LANES ARE TO BE A BOOMLESS TYPE NOZZLE THAT MOUNTS ON THE
ENDS OF THE CENTER SPRAY BAR. IT IS ATTACHED TO A GALVANIZED
STEEL SUPPORT DESIGNED FOR MOUNTING IN A 2" X 2" TRAILER
HITCH RECEIVER. HOSE FROM THE PUMP TO THE SPRAY BAR IS 1" DIAMETER
AND CONTAINS A PRESSURE CHECK VALVE TO PREVENT SIPHONING FROM THE
TANK WHEN PUMP IS OFF. LANE COVERAGE CAN BE ADJUSTED FROM 8' TO 12'
WIDE. THE SPRAY BARS ARE INDIVIDUALLY CONTROLLED BY THE OPERATOR FROM
THE CAB WITH THREE (3) ELECTRIC ACTUATED POLY BALL VALVES.

PLUMBING

TANK VALVE - 2" POLYPROPYLENE
3 BANK ELECTRIC VALVES - 1" OUTLET TO SPRAY BAR, 12 V DC POWER,
PLUNGER STYLE VALVE, POLY HOUSING
BY-PASS CONTROL - 2 EACH 1" POLY BALL VALVES FOR MANUAL CONTROL
RECIRCULATION/BYPASS LINE - 1" RUBBER RETURN TO TANK WITH POLY
BULKHEAD
LINE STRAINER - 2" POLYPROPYLENE WITH 80 MESH STAINLESS STEEL SCREEN
FITTINGS - POLYPROPYLENE OR PVC SHE 80
HOSE CLAMPS - STAINLESS STEEL

CAB CONTROL

GROUND SPEED CONTROLLER MUST CONTROL BOTH ANTI-ICING AND HERBICIDE
APPLICATION.

HOSE REEL

MANUAL HOSE REEL WITH 50' OF 1" HIGH PRESSURE HOSE WITH 17" ADJUSTABLE
SPRAY WAND. (HYPRO MODEL 3381 OR EQUAL)

TANK BAFFLE SYSTEM

THE TANK SHALL CONTAIN A TOTAL BAFFLE SYSTEM. THE BAFFLE SYSTEM SHALL
FILL THE 500 GALLON POLYETHYLENE TANK AND COMPLETELY ELIMINATE UNSAFE
CONDITIONS RESULTING FROM THE LIQUID SLOSH ASSOCIATED WITH MOBILE
POLY TANKS WHICH ARE NOT BAFFLED.

REQUIRED HERBICIDE CONVERSION

UNIT TO HAVE 3 NOZZLE STREAM TO SPRAY 3 APPLICATIONS:
(1) WIDTH BESIDE ROADWAY; (2) GUARDRAIL; (3) DITCH BANK
NOTE: THREE (3) MANUAL CHANGE OVER VALVES REQUIRED TO SWITCH FROM
SUMMER TO WINTER APPLICATIONS.

GROUND SPEED CONTROL SYSTEM SPECIFICATIONS ARE THE SAME AS LISTED
FOR LINE ITEM 11 AND 12.

SPECIFICATIONS FOR LINE ITEM 00013: APPLICATOR W/GROUND SPEED CONTROL
(1000 GALLON)

DESCRIPTION

DIRECT APPLICATION SYSTEM DESIGNED TO APPLY LIQUID ANTI-ICERS AND
DEICERS DIRECTLY TO THE ROAD SURFACE FROM THE MINIMUM 1000 GALLON
FRAME MOUNT TANK IN A 37,000 GVWR DUMP TRUCK. SPRAY NOZZLES ARE
STRAIGHT STREAM AND WILL COVER 8' TO 12' WIDE. SYSTEM IS A SLIDE IN
TYPE FOR EASY LOAD AND UNLOAD WITH A FORKLIFT. THE PUMP SHALL BE
HYDRAULICALLY DRIVEN.

TANK

THE HORIZONAL LEG TANK HAS A CAPACITY OF 1000 GALLONS (MINIMUM) AND IS
RATED FOR MATERIALS UP TO 16 LBS. PER GALLON. IT IS ROTATIONALLY
MOLDED OF HIGH IMPACT LINEAR POLYETHYLENE WITH UV STABILIZERS. IT HAS
A 16" VENTED MAN WAY AND A 2" NPT OUTLET. THREE (3) GALVANIZED STEEL
BANDS ATTACH THE TANK TO THE FRAME.

TANK FRAME

THE TANK FRAME IS FABRICATED STEEL, HOT DIP GALVANIZED OR STAINLESS
STEEL FOR CORRISSION PROTECTION. IT HOLDS THE TANK, PUMP UNIT
AND PLUMBING. IT IS FORMED TO ALLOW FOR ACCESS BY FORKLIFT FOR EASY
LOADING & UNLOADING. TANK FRAME MUST HAVE A 10 GUAGE DECK FOR MOUNTING
PLUMBING APPROX. 24" X 82". TANK FRAME MUST HAVE HINGED ANTI-ICING AND
HERBICIDE SPRAY BAR MOUNTS ON REAR.

PUMP UNIT

HYDRAULIC MOTOR DRIVE. MAXIMUM MOTOR PSI 2000 CONTINOUS DUTY
PUMP HOUSING SHALL BE CAST IRON AND THE PUMP IMPELLER SHALL BE
CAST IRON. PORT SIZES: 2" NPT INPORT INLET AND 1.5"
NPT OUTLET. MAXIMUM UNRESTRICTED FLOW RATE SHALL BE 214 GPM
INLET 2" AND 1.5" NPT OUTLET.

SPRAY BAR

THREE (3) LANE COVERAGE, ALL SPRAY BAR TO BE 1.5" SCHEDULE 80 PVC. ALL
SPRAY NOZZLES TO BE BRASS, STRAIGHT STREAM, QUICK-CHANGE, MOUNTED IN
16 DEGREE SWIVEL MOUNT, WHICH CLIPS TO THE SPRAY BOOM. EACH SPRAY BOOM
TO HAVE A 5 PSI INLINE DIAPHRAGM CHCEK VALVE. CENTER SPRAY BOOM TO
HAVE (10) NOZZLE ASSEMBLIES AND SHALL BE ADJUSTABLE FROM 12" TO 18" IN
HEIGHT FROM THE PAVEMENT. SIDE LANE BOOMS SHALL HAVE (4) TO (6) NOZZLE
ASSEMBLIES TO COVER THE LEFT AND RIGHT LANES. ALL SPRAY BOOMS TO BE
INDEPENDENTLY CONTROLLED BY ELECTRIC ON/OFF BALL VALVES MANIFOLD
TOGETHER. ENTIRE ASSEMBLY SHALL PIVOT INTO STORAGE POSITION WHEN NOT
IN USE AND BE SECURED WITH HITCH PINS.

PLUMBING

TANK VALVE - 2" POLYPROPYLENE
3 BANK ELECTRIC VALVES - 1" OUTLET TO SPRAY BAR, 12 V DC POWER,
PLUNGER STYLE VALVE, POLY HOUSING
BY-PASS CONTROL - 2 EACH, 1 1/2" POLY BALL VALVES FOR MANUAL CONTROL
RECIRCULATION/BYPASS LINE - 1" RUBBER RETURN TO TANK WITH POLY
BULKHEAD

LINE STRAINER - 2" POLYPROPYLENE WITH 80 MESH STAINLESS STEEL SCREEN
FITTINGS - POLYPROPYLENE OR PVC SHC 80
HOSE CLAMPS - STAINLESS STEEL

CAB CONTROL

GROUND SPEED CONTROLLER SHALL CONTROL ANTI-ICING AND HERBICIDE
APPLICATION.

HOSE REEL

MANUAL HOSE REEL WITH 50' OF 1" HIGH PRESSURE HOSE WITH 17" ADJUSTABLE
SPRAY WAND. (HYPRO MODEL 3381 OR EQUAL)



TANK BAFFLE SYSTEM

THE TANK SHALL CONTAIN A TOTAL BAFFLE SYSTEM. THE BAFFLE SYSTEM SHALL
FILL THE 1000 GALLON POLYETHYLENE TANK AND COMPLETELY ELIMINATE UNSAFE
CONDITIONS RESULTING FROM THE LIQUID SLOSH ASSOCIATED WITH MOBILE
PLY TANKS WHICH ARE NOT BAFFLED.

REQUIRED HERBICIDE CONVERSION

UNIT TO HAVE 3 NOZZLE STREAM TO SPRAY THREE (3) APPLICATIONS:
(1) WIDTH BESIDE ROADWAY; (2) GUARDRAIL; (3) DITCH BANK.
NOTE: THREE (3) MANUAL CHANGE OVER QUICK COUPLERS RQUIRED TO SWITCH
FROM SUMMER TO WINTER APPLICATIONS. ASSEMBLY TO BE REMOVABLE AND
ABLE TO SWITCH FROM RIGHT OR LEFT SIDE OF TRUCK WITH NO TOOLS.
ASSEMBLY MUST BE ATTAHCED TO SPRAYER STEEL FRAME. MUST BE ABLE
TO BE STOWED ON UNIT WHEN NOT IN USE.

GROUND SPEED CONTROL SYSTEM SPECIFICATIONS ARE THE SAME AS LISTED
FOR LINE 11 AND 12.


SPECIFICATIONS FOR LINES 00014, 00016, 00018: PUMP, GAS ENGINE-DRIVEN

PUMP SHALL BE CLOSE-COUPLED WITH A MAXIMUM FLOW RATE OF 150 GPM AT
140 PSI. PORT SIZES: 2" NPT INLET, 1.5" NPT OUTLET. HOUSING SHALL BE
CAST IRON. IMPELLER SHALL BE GLASS-FILLED NYLON. HONDA 9 HP MINIMUM


SPECIFICATIONS FOR LINE ITEM 00015: APPLICATOR W/GROUND SPEED CONTROL
(1800 GALLON)

DESCRIPTION

DIRECT APPLICATION SYSTEM IS DESIGNED TO APPLY LIQUID ANTI-ICERS AND
DEICERS DIRECTLY TO THE ROAD SURFACE FROM A 1800 GALLON FRAME MOUNT
TANK ON A 46,000 GVWR TANDEM DUMP TRUCK. SPRAY NOZZLES ARE STRAIGHT
STREAM AND WILL COVER 8' TO 12' WIDE. THE SYSTEM IS A SLIDE IN TYPE
FOR EASY LOAD AND UNLOAD WITH A FORKLIFT. THE PRODUCT PUMP SHALL BE
HYDRAULIC POWERED.

TANK

THE HORIZONTAL LEG TANK HAS A CAPACITY OF 1800 GALLONS AND IS RATED
FOR MATERIALS UP TO 16 LBS. PER GALLON. IT IS ROTATIONALLY MOLDED OF
HIGH IMPACT LINEAR POLYETHYLENE WITH UV STABILIZERS. IT HAS A 16"
VENTED MAN WAY AND A 2" NPT OUTLET. FOUR (4) GALVANIZED STEEL BANDS
ATTACH THE TANK TO THE FRAME.

TANK FRAME

THE TANK FRAME IS FABRICATED STEEL, HOT DIP GALVANIZED OR STAINLESS
STEEL FOR CORRISSION PROTECTION. IT HOLDS THE TANK, PUMP UNIT, AND
PLUMBING. IT IS FORMED TO ALLOW FOR ACCESS BY FORKLIFT FOR EASY
LOADING & UNLOADING. PLUMBING SHALL BE MOUNTED ON A 10 GUAGE DECK THAT
IS APPROX. 24" X 82". HINGED ANTI-ICING AND HERBICIDE SPRAY BAR MOUNTS
MUST BE INCLUDED ON THE REAR OF THE MAIN FRAME.

PUMP UNIT

HYDRAULIC MOTOR DRIVE. MAXIMUM MOTOR PSI 2000 CONTINOUS DUTY
PUMP HOUSING SHALL BE CAST IRON AND THE PUMP IMPELLER SHALL BE
CAST IRON. PORT SIZES: 2" NPT INPORT INLET AND 1.
NPT OUTLET. MAXIMUM UNRESTRICTED FLOW RATE SHALL BE 214 GPM
INLET 2" AND 1.5" NPT OUTLET.

SPRAY BAR

THREE (3) LANE COVERAGE, ALL SPRAY BARS TO BE 1.5" SCHEDULE 80 PVC.
ALL APRAY NOZZLES TO BE BRASS, STRAIGHT STREAM, QUICK-CHANGE, MOUNTED
IN 16 DEGREE SWIVEL MOUNT, WHICH CLIP TO THE SPRAY BOOM. EACH SPRAY
BOOM TO HAVE A 5 PSI INLINE DIAPHRAGM CHECK VALVE. CENTER SPRAY BOOM
TO HAVE (10) NOZZLE ASSEMBLIES AND SHALL BE ADJUSTABLE FROM 12" TO 18"
IN HEIGHT FROM PAVEMENT. SIDE LANE BOOMS SHALL HAVE (4) TO (6) NOZZLE
ASSEMBLIES TO COVER THE LEFT AND RIGHT LANES. ALL SPRAY BOOMS TO BE
INDEPENDENTLY CONTROLLED BY ELECTRIC ON/OFF BALL VALVES MANIFOLD
TOGETHER. ENTIRE ASSEMBLY SHALL PIVOT INTO STORAGE POSITION WHEN NOT
IN USE AND BE SECURED WITH HITCH PIN.

PLUMBING

TANK VALVE - 2" POLYPROPYLENE
3 BANK ELECTRIC VALVES - 1" OUTLET TO SPRAY BAR, 12 V DC POWER,
PLUNGER STYLE VALVE, POLY HOUSING
BY-PASS CONTROL - 2 EACH 1" POLY BALL VALVES FOR MANUAL CONTROL
RECIRCULATION/BYPASS LINE - 1 1/2" RUBBER RETURN TO TANK WITH POLY
BULKHEAD

LINE STRAINER - 2" POLYPROPYLENE WITH 80 MESH STAINLESS STEEL SCREEN
FITTINGS - POLYPROPYLENE OR PVC SCH 80
HOSE CLAMPS - STAINLESS STEEL

CAB CONTROL

GROUND SPEED CONTROLLER MUST CONTROL ANTI-ICING AND HERBICIDE
APPLICATION.

HOSE REEL

MANUAL HOSE REEL WITH 50' OF 1" HIGH PRESSURE HOSE WITH 17" ADJUSTABLE
SPRAY WAND. (HYRPO MODEL 3381 OR EQUAL)

TANK BAFFLE SYSTEM

THE TANK SHALL CONTAIN A TOTAL BAFFLE SYSTEM. THE BAFFLE SYSTEM SHALL
FILL THE 1800 GALLON POLYETHYLENE TANK AND COMPLETELY ELIMINATE UNSAFE
CONDITIONS RESULTING FROM THE LIQUID SLOSH ASSOCIATED WITH MOBILE
POLY TANKS WHICH ARE NOT BAFFLED.

REQUIRED HERBICIDE CONVERSION

UNIT TO HAVE 3 NOZZLE STREAM TO SPRAY 3 APPLICATIONS:
(1) WIDTH BESIDE ROADWAY; (2) GUARDRAIL; (3) DITCH BANK
NOTE: THREE (3) MANUAL CHANGE OVER QUICK COUPLERS REQUIRED TO SWITCH
FROM SUMMER TO WINTER APPLICATIONS. ASSEMBLY MSUT BE REMOVEABLE
AND ABLE TO SWITCH FROM RIGHT OR LEFT SIDE OF TRUCK WITH NO
TOOLS. ASSEMBLY MUST BE ATTACHED TO SPRAYER STEEL FRAME. MUST BE
ABLE TO BE STOWED WHEN NOT IN USE.

GROUND SPEED CONTROL SYSTEM SPECIFICATIONS ARE THE SAME AS LISTED
FOR LINE ITEM 12.


SPECIFICATIONS FOR LINE ITEM 00017: APPLICATOR W/GROUND SPEED CONTROL
(2600 GALLON)

DESCRIPTION

DIRECT APPLICATION SYSTEM DESIGNED TO APPLY LIQUID ANTI-ICERS AND
DEICERS DIRECTLY TO THE ROAD SURFACE FROM THE MINIMUM 2600 GALLON
FRAME MOUNT TANK IN A 74,000 GVWR TRI-AXLE DUMP TRUCK. SPRAY NOZZLES
ARE STRAIGHT STREAM AND WILL COVER 8' TO 12' WIDE. SYSTEM IS A SLIDE
IN TYPE FOR EASY LOAD AND UNLOAD WITH A FORKLIFT. THE PUMP SHALL BE
HYDRAULICALLY DRIVEN.

TANK

THE HORIZONAL LEG TANK HAS A CAPACITY OF 2600 GALLONS (MINIMUM) AND IS
RATED FOR MATERIALS UP TO 16 LBS. PER GALLON. IT IS ROTATIONALLY
MOLDED OF HIGH IMPACT LINEAR POLYETHYLENE WITH UV STABILIZERS. IT HAS
A 16" VENTED MAN WAY AND A 2" NPT OUTLET. FOUR (4) GALVANIZED STEEL
BANDS ATTACH THE TANK TO THE FRAME.

TANK FRAME

THE TANK FRAME IS FABRICATED STEEL, HOT DIP GALVANIZED OR STAINLESS
STEEL FOR CORRISSION PROTECTION. IT HOLDS THE TANK, PUMP UNIT
AND PLUMBING. IT IS FORMED TO ALLOW FOR ACCESS BY FORKLIFT FOR EASY
LOADING & UNLOADING. PLUMBING SHALL BE MOUNTED ON A 10 GUAGE DECK
APPROX. 24" X 82". HINGED ANTI-ICING AND HERBICIDE SPRAYER MUST BE
MOUNTED ON THE REAR OF THE FRAME.

PUMP UNIT

HYDRAULIC MOTOR DRIVE. MAXIMUM MOTOR PSI 2000 CONTINOUS DUTY
PUMP HOUSING SHALL BE CAST IRON AND THE PUMP IMPELLER SHALL BE
CAST IRON. PORT SIZES: 2" NPT INPORT INLET AND 1.5"
NPT OUTLET. MAXIMUM UNRESTRICTED FLOW RATE SHALL BE 214 GPM
INLET 2" AND 1.5" NPT OUTLET.

SPRAY BAR

THREE (3) LANE COVERAGE, ALL SPRAY BARS TO BE 1.5" SCHEDULE 80 PVC.
ALL SPRAY NOZZLES TO BE BRASS, STRAIGHT STREAM, QUICK-CHANGE, MOUNTED
IN 16 DEGREE SWIVEL MOUNT, WHICH CLIPS TO THE SPRAY BOOM. EACH SPRAY
BOOM TO HAVE A 5 PSI INLINE DIAPHRAGM CHECK VALVE. CENTER SPRAY BOOM
TO HAVE (10) NOZZLE ASSEMBLIES AND SHALL BE ADJUSTABLE FROM 12" TO 18"
IN HEIGHT FROM THE PAVEMENT. SIDE LANE BOOMS SHALL HAVE (4) TO (6)
NOZZLE ASSEMBLIES TO COVER THE LEFT AND RIGHT LANES. ALL SPRAY BOOMS
TO BE INDEPENDENTLY CONTROLLED BY ELECTRIC ON/OFF BALL VALVE MANIFOLD
TOGETHER. ENTIRE ASSEMBLY SHALL PIVOT INTO STORAGE WHEN NOT IN USE AND
BE SECURED WITH HITCH PINS.

PLUMBING

TANK VALVE - 2" POLYPROPYLENE
3 BANK ELECTRIC VALVES - 1" OUTLET TO SPRAY BAR, 12 V DC POWER,
PLUNGER STYLE VALVE, POLY HOUSING
BY-PASS CONTROL - 2 EACH, 1" POLY BALL VALVES FOR MANUAL CONTROL
RECIRCULATION/BYPASS LINE - 1 1/2" RUBBER RETURN TO TANK WITH POLY
BULKHEAD

LINE STRAINER - 2" POLYPROPYLENE WITH 80 MESH STAINLESS STEEL SCREEN
FITTINGS - POLYPROPYLENE OR PVC SHC 80
HOSE CLAMPS - STAINLESS STEEL

CAB CONTROL

GROUND SPEED CONTROLLER MUST CONTROL ANTI-ICING AND HERBICIDE
APPLICATION.

HOSE REEL

MANUAL HOSE REEL WITH 50' OF 1" HIGH PRESSURE HOSE WITH 17" ADJUSTABLE
SPRAY WAND.(HYPRO MODEL 3381 OR EQUAL)

TANK BAFFLE SYSTEM

THE TANK SHALL CONTAIN A TOTAL BAFFLE SYSTEM. THE BAFFLE SYSTEM SHALL
FILL THE 2600 GALLON POLYETHYLENE TANK AND COMPLETELY ELIMINATE UNSAFE
CONDITIONS RESULTING FROM THE LIQUID SLOSH ASSOCIATED WITH MOBILE
PLY TANKS WHICH ARE NOT BAFFLED.

REQUIRED HERBICIDE CONVERSION

UNIT TO HAVE 3 NOZZLE STREAM TO SPRAY THREE (3) APPLICATIONS:
(1) WIDTH BESIDE ROADWAY; (2) GUARDRAIL; (3) DITCH BANK.
NOTE: THREE (3) MANUAL CHANGE OVER QUICK COUPLERS RQUIRED TO SWITCH
FROM SUMMER TO WINTER APPLICATIONS. ASSEMBLY MUST BE REMOVEABLE`
AND ABLE TO SWITCH FROM RIGHT OR LEFT SIDE OF TRUCK WITH NO
TOOLS. ASSEMBLY MUST BE ATTACHED TO SPRAYER STEEL FRAME. MUST BE
ABLE TO BE STOWED WHEN NOT IN USE.

GROUND SPEED CONTROL SYSTEM SPECIFICATIONS ARE THE SAME AS LISTED
FOR LINE 12.

SPECIFICATIONS FOR LINE ITEM 00019: FRAME MOUNTED PRE-WET SYSTEM
(135 GALLON TANK)

NOTE: UNIT MUST BE FULLY ASSEMBLED READY FOR IMMEDIATE USE

DESCRIPTION

THE TAILGATE PRE-WET SYSTEM SHALL BE DESIGNED TO BE CAPABLE OF
MAINTAINING A CONSISTENT RATIO OF LIQUID PRE-WET SOLUTIONS TO A
PRE-DETERMINED GRANULAR DEICING MATERIAL OUTPUT. THIS SYSTEM IS PLACED
IN SERIES WITH THE TRUCK'S HYDRAULIC DRIVEN AUGER MOTOR. THE SYSTEM
TANK WITH PUMP UNIT IS MOUNTED ON THE TAILGATE SO AS NOT TO
INTERFERE WITH THE LOADING OF SALT ON THE SPREADER OF THE TRUCK. THE
TANK FRAME AND MOUNTING BRACKETS ARE MILD STEELHOT DIP GALVANIZED OR
OR 304 STAINLESS STEEL FOR CORROSION PROTECTION ANDDESIGNED FOR EASY
INSTALLATION.

THE HYDRAULIC POWER UNIT (PUMP ENCLOSURE) IS MOUNTED IN A POSITION TO
BE EASILY ACCESSIBLE FOR INSPECTION AND MAINTENANCE. THE CHEMICAL PUMP
OUTLET IS CONNECTED TO THE SPRAY NOZZLE (1 EACH), THAT IS MOUNTED ON
OR ABOVE THE SPREADER'S SPINNER.

COMPONENT CONFIGURATION

THE RESERVOIR TANK AND HYDRAULIC SYSTEM ENCLOSURE ARE MOUNTED ON A HOT
DIP GALVANIZED STEEL OR STAINLESS STEEL CARRIER WHICH IS ATTACHED TO
THE TAILGATE OF SALT SPREADER TRUCKS. THE CARRIER IS CONSTUCTED OF HOT
ROLLED STEEL AND IS DESIGNED FOR QUICK INSTALLATION AND REMOVAL FROM
THE TAILGATE USING TWO "PULL PINS". THE CARRIER ALSO SHALL INCORPORATE
A LIFTING EYE INTO THE DESIGN TO FACILITATE EASY INSTALLATION AND
REMOVAL OF THE SYSTEM AS NEEDED. THE CHEMICAL PUMP OUTLET SHALL BE
CONNECTED TO THE SPREADER MOUNTED SPRAY NOZZLES BY NYLON RE-INFORCED
PVC HOSE. A BRASS QUICK DISCONNECT, WITH INTEGRAL CHECK VALVE, SHALL
BE ININCLUDED IN THE LIQUID LINE TO FACILITATE EASY REMOVAL.
THE SYSTEM CONTROLS SHALL BE CAB MOUNTED AND CONNECTED TO THE POWER
UNIT WITH SHIELDED 4-WIRE CONTROL CABLE WITH WEATHERPACK CONNECTORS.

HYDRAULIC POWER/PUMP MOTOR

ALL HYDRAULIC/PUMP COMPONENTS ARE ENCLOSED IN A ROTATIONALLY MOLDED
POLYETHYLENE OR STAINLESS STEEL HOUSING AND ARE MOUNTED ON A STAINLESS
STEEL PLATE. THE ENCLOSURE DIMENSIONS ARE APPROXIMATELY 18" X 7" X 12"
(WX D X H). THE COVER IS HELD IN PLACE WITH TWO RUBBER LATCHES
MOUNTED WITH STAINLESS STEEL HARDWARE.
A 12" STAINLESS STEEL LANYARD ATTACHES THE LID TO THE
ENCLOSURE BOX. CONNECTED TO THE EXTERIOR OF THE ENCLOSURE, AT THE
SUCTION SIDE OF THE PRODUCT PUMP, SHALL BE A 12-MESH STAINLESS STEEL,
T-STRAINER FOR REMOVAL OF PARTICULATE MATTER.
THE PUMP SHALL BE BRASS, CLOSE COUPLED TO THE CAST IRON HYDRAULIC
MOTOR. THE BRASS PUMP SHALL HAVE BRONZE GEARS WITH STAINLESS STEEL
SHAFT, CARBON BEARINGS, AND .5" PORTS FOR SUCTION AND DISCHARGE. THE
PUMP SHALL BE CAPABLE OF A FLOW RATE OF 8.7 GALLONS PER MINUTE AT 20
PSI WITH 4.5 GALLONS OF HYDRAULC FLOW.
THE HYDRALUIC MOTOR SHALL BE INTERNAL GEAR GEAROTOR STYLE WITH DOUBLE
LIP TEFLON SEAL, BYPASS ADJUSTMENT FOR ADJUSTING FLOW CONTROL AND .5"
PRESSURE AND RETURN PORTS. HYDRAULIC FLOW TO THE MOTOR SHALL BE
CONTROLLED BY AN ELECTRICAL ACTUATED SOLENOID VALVE. AN ADJUSTABLE
PRESSURE REGULATOR CHCEK VALVE SHALL BE INCLUDED TO BALANCE PRESSURE
THE SOLENOID VALVE.

TANK

THE TANKS ARE CONSTRUCTED OF ROTATIONALLY MOLDED HIGH-DENSITY
POLYETHYLENE, WHICH IS UV STABILIZED. TANKS ARE DESIGNED TO HOLD
LIQUID PRE-WET MATERIALS WITH SPECIFIC GRAVITY OF UP TO 16 LBS. PER
GALLON. THE TANK SHALL HAVE MOLDED IN ANTI SLOSH BAFFLES. THE TANK
FITTINGS SHALL INCLUDE A 5" TOP FILL OPEING WITH VENTED LID AND TETHER
AND BULKHEAD STYLE FITTINGS FOR BOTTOM FILL, LEVEL SWITCH, AND
OUTLET PUMP. A SINGLE QUICK COUPLE CONNECTION WITH VALVE SHALL BE
INCLUDED FOR BOTTOM FILL. ALL HOSES SHALL BE NYLON REINFORCED PVC.
ALL VALVES AND FITTINGS SHALL BE PVC/POLYPROPYLENE. DIMENSIONS OF
THE TANK SHALL NOT INTERFERE WITH OR BLOCK THE VISIBILITY OF THE
TRUCK'S TAILIGHTS.
TANK DIMENSIONS: 26.5" HIGH X 70" LONG X 20" WIDE

SPRAY NOZZLES

CONSTRUCTED OF BRASS, THE SPRAY NOZZLE (1) ARE DESIGNED TO MAINTAIN
A 120 DEGREE FAN SPRAY THROUGHOUT THE SYSTEM CHEMICAL FLOW RATE.

FITTINGS AND VALVES

ALL CHEMICAL PLUMBING FITTINGS AND VALVES ARE PVC AND POLYPROPYLENE.
ALL HOSE IS NYLON REINFORCED PVC. THE SYSTEM USES AN ACCESSIBLE
IN-LINE STRAINER WITH 20 MESH SCREEN. THE FILL POINT USES A 1" QUICK
CONNECT POLYPROPYLENE COUPLING AND IS A BOTTOM FILL SYSTEM. THE TANK
IS VENTED FOR BOTTOM FILL.

IN CAB CONTROLS

MOUNTED IN THE CAB, THE CONTROL CONSOLE IS COMPLETE WITH SYSTEM POWER
ON/OFF SWITCH WITH INDICATOR LIGHTS, AUDIBLE BUZZER AND SYSTEM
SHUTDOWN RELAY WHICH IS INTEGRATED INTO THE CIRCUITRY. THE CONTROL
CONSOLE IS ATTACHED USING TWO MOUNTING BRACKETS SUPPLIED. IT SHALL BE
ELECTRICALLY PROTECTED WITH A FUSED CONNECTION.

LEVEL SENSOR

THE LEVEL SENSOR ALERTS THE OPERATOR WHEN THE PRODUCT LEVEL IN THE
TANK DROPS TO NEAR EMPTY. THE FLOAT TYPE SENSOR WILL ACTIVATE THE
CAB CONTROL LIGHT AND AUDIBLE BUZZER TO ALERT THE OPERATOR. IT SHALL
ALSO SHUT DOWN THE SYSTEM TO PREVENT PUMP DAMAGE.

FLUSH ASSEMBLY

LOCATED AT THE SUCTION SIDE OF THE PUMP, BETWEEN THE "T" STRAINER AND
THE TANK. SHALL HAVE A .5" 3 WAY PVC BALL VALVE ASSEMBLY. ITS FUNCTION
IS TO ALLOW FLOW FROM THE TANKS TO THE PUMP FOR NORMAL OPERATION. IT
ALSO ALLOWS FLOW VIA A GARDEN HOSE ADAPTER, THROUGH THE "T" STRAINER,
PUMP, AND SPRAY NOZZLES, TO FLUSH THE PRE-WET LIQUID FROM THE WORKING
COMPONENTS OF THE SYSTEM DURING PERIODS OF NON-USE.

PARTS MANUAL

INCLUDED WITH SYSTEM SHALL BE A COMPLETE PARTS MANUAL, INSTALLATION/
OPERATION/MAINTENANCE INSTRUCTIONS.



SPECIFICATIONS FOR LINE ITEM 00020: FRAME MOUNTED PRE-WET SYSTEM
(65 GALLON TANK)

NOTE: UNIT MUST BE FULLY ASSEMBLED READY FOR IMMEDIATE USE

DESCRIPTION

THE FRAME MOUNTED PRE-WET SYSTEM IS DESIGNED TO BE CAPABLE OF
MAINTAINING A CONSISTENT RATIO OF LIQUID PRE-WET SOLUTIONS TO A
PRE-DETERMINED GRANULAR DEICING MATERIAL OUTPUT. THIS SYSTEM WILL
OPERATE IN CONJUNCTION WITH MANUAL HYDRAULIC FLOAT CONTROL VALVE
LOCATED IN CAB OF TRUCK (1 DAIL FOR SPINNER, 1 DIAL FOR AUGER).
OPERATOR CONTROLS SPEED OF AUGER & SPINNER IN RELATION TO THE SPEED
OF THE TRUCK. THE SYSTEM TANK AND PUMP UNIT ARE MOUNTED ON THE FRAME
RAIL OF THE TRUCK. THE TANK FRAME AND MOUNTING BRACKETS ARE MILD STEEL
HOT DIP GALVANIZED OR 304 STAINLESS STEEL FOR CORROSION PROTECTION AND
DESIGNED FOR EASY INSTALLATION. THE SYSTEM WILL OPERATE IN AUGER
REVERSE WITHOUT ANY BACK PRESSURE ON THE SYSTEM COMPONENTS. THE PUMP
UNIT IS MOUNTED ON THE SAME STEEL PLATE THAT THE TANK IS MOUNTED.

THE HYDRAULIC POWER UNIT (PUMP ENCLOSURE) IS MOUNTED IN A POSITION TO
BE EASILY ACCESSIBLE FOR INSPECTION AND MAINTENANCE. IT IS CONNECTED
IN SERIES WITH THE SPREADER'S AUGER MOTOR. THE CHEMICAL PUMP IS
CONNECTED TO THE SPRAY NOZZLES (2 EACH) WHICH ARE MOUNTED ON OR ABOVE
THE SPREADER'S DROP CHUTE. THE RESEVOIR TANK IS MOUNTED ON TWO FORMED
STEEL "L" BRACKETS.

COMPONENT CONFIGURATION

THE RESERVOIR TANK AND HYDRAULIC SYSTEM ENCLOSURE ARE MOUNTED ON A HOT
DIP GALVANIZED STEEL OR STAINLESS STEEL FRAME, MEETING
ASTM SPECIFICATION A-123, WHICH IS ATTACHED TO THE
FRAME RAIL TRUCK. THE STEEL CARRIER IS CONSTRUCTED
OF FORMED MILD STEEL OR 304 STAINLESS STEEL AND IS DESIGNED TO BE
PERMANENTLY MOUNTED TO THE FRAME OF THE TRUCK. THE CHEMICAL PUMP
OUTLET IS CONNECTED TO THE SPREADER MOUNTED SPRAY NOZZLES BY NYLON
RE-ENFORCED PVC HOSE. A QUICK DISCONNECT IS INCLUDED IN THE LIQUID
LINE TO FACILITATE EASY REMOVAL. THE SYSTEM CONTROLS ARE CAB-MOUNTED
AND ARE CONNECTED TO THE POWER UNIT WITH SHIELDED 4-WIRE CONTROL CABLE
WITH WEATHERPACK CONNECTORS. ALSO SHALL INCLUDE A NEMA 4X PLASTIC OR
FIBERGLASS JUNCTION BOX WITH MOISTURE TIGHT CABLE GRIPS.

HYDRAULIC POWER/PUMP MOTOR

MOUNTED ON A STAINLESS STEEL PLATE ALL HYDRAULIC/PUMP COMPONENTS ARE
ENCLOSED IN AN UNSEALED ROTATIONALLY MOLDED POLYETHYLENE OR STAINLESS
STEEL HOUSING. THE ENCLOSURE DIMENSIONS ARE APPROXIMATELY 18" X 7" X
12" (W X D X H). THE COVER IS HELD IN PLACE WITH TWO RUBBER LATCHES
MOUNTED WITH STAINLESS STEEL HARDWARE.
A 12" STAINLESS STEEL LANYARD ATTACHES THE LID TO THE
ENCLOSURE BOX. CONNECTED TO THE EXTERIOR OF THE ENCLOSURE, AT THE
SUCTION SIDE OF THE PRODUCT PUMP, IS A 12-MESH STAINLESS STEEL,
T-STRAINER FOR REMOVAL OF PARTICULATE MATTER, WHICH MAY HARM THE
PUMP OR RESTRICT FLOW THROUGH THE NOZZLES. THE SYSTEM INCORPORATES A
FULL FLOW BY-PASS VALVE THAT WILL DIVERT ALL HYDRAULIC FLOW, UP TO
15 GPM, FROM THE PUMP SYSTEM. TO ALLOW FOR PROPORTIONAL LIQUID DEICER
SOLUTION ADJUSTMENT THE SYSTEM USES AN ADJUSTABLE RATIO FLOW
CONTROLLER LOCATED IN THE POWER UNIT ENCLOSURE. AN ELECTRIC ACTIVATED
SOLENOID VALVE, CONTROLLED FROM THE CAB, OPERATES THE ON/OFF FUNCTION
OF THE SYSTEM ALLOWING HYDRAULIC FLOW THROUGH THE CONTROL BLOCK. THE
HYDRAULIC MOTOR IS CAST IRON, INTERNAL GEAR GEROTOR DESIGN WITH
.625 CID CAPACITY, DOUBLE-LIP TEFLON SEAL, WITH 1/2" NPT PORTS. IT IS
DIRECT COUPLED TO THE PRODUCT PUMP WHICH ELIMINATES THE NEED FOR A
LOVEJOY TYPE COUPLER. THE PRODUCT PUMP, BRONZE ROTARY GEAR, POSITIVE
DISPLACEMENT, WITH STAINLESS STEEL SHAFT, CARBON BEARINGS, HAS A FLOW
RATE OF 8.7 GPM AT 20 PSI WITH 4.5 GALLONS OF HYDRAULIC FLOW.
ALL HYDRAULIC HOSES IN THE ENCLOSURE ARE FLEXIBLE.

TANK

THE 65 GALLON TANK IS CONSTRUCTED OF ROTATIONALLY MOLDED HIGH-DENSITY
POLYETHYLENE, WHICH IS UV STABILIZED. TANKS ARE DESIGNED TO HOLD
LIQUID PRE-WET MATERIALS WITH SPECIFIC GRAVITY OF UP TO 16 LBS. PER
GALLON. A PVC/POLYPROPYLENE VALVE IS PROVIDED AT THE TANK OUTLET TO
THE PUMP. THE TANK IS EQUIPPED WITH A 5" TOP FILL OPENING WITH VENTED
LID. THE TANK IS ATTACHED WITH TWO HEAVY DUTY GALVANIZED
STEEL OR STAINLESS STEEL ADJUSTABLE BANDS. INSTALLED IN THE
TANK IS A LEVEL SWITCH WHICH IS CONNECTED TO THE CAB CONTROL FOR
AUTOMATIC SYSTEM SHUTDOWN WHEN THE TANK IS EMPTY. TANKS SHALL NOT
EXCEED 23" DIAMETER X 43" LENGTH. COLOR TO BE WHITE.

SPRAY NOZZLES

CONSTRUCTED OF BRASS, THE SPRAY NOZZLE IS DESIGNED TO MAINTAIN
A 120 DEGREE FAN SPRAY THROUGHOUT THE SYSTEM CHEMICAL FLOW RATE.
A 304 STAINLESS STEEL NOZZLE MOUNTING PLATE, 16 GUAGE 2" X 3.5" WITH
A 11/16" SPACED CENTER 1.25" FROM ONE END TO BE INCLUDED.

FITTINGS AND VALVES

ALL CHEMICAL PLUMBING FITTINGS AND VALVES ARE FLEXIBLE TYPE PVC
OR POLYPROPLENE. ALL HOSE IS NYLON REINFORCED PVC. THE SYSTEM
USES AN ACCESSIBLE IN-LINE STRAINER WITH 20 MESH SCREEN. THE FILL
POINT USES A 1" QUICK CONNECT POLYPROPYLENE COUPLING AND IS A BOTTOM
FILL SYSTEM. THE TANK IS VENTED FOR BOTTOM FILL. HOSE CLAMPS TO
BE STAINLESS STEEL. TANK VALVE WILL BE .75" POLYPROPLENE 3-WAY SIDE
LOAD TYPE WITH 1" FEMALE QUICK COUPLE CONNECTION AND DUST PLUG, .75"
BRASS NIPPLE, AND 1/2 POUND CHECK VALVE TO AID IN MAINTAINING PUMP.
A .5" "T" STRAINER WILL BE PLACED IN LINE BETWEEN THE PUMP SUCTION AND
THE TANK. THIS WILL PREVENT PARTICULATE MATTER FROM DAMAGING THE PUMP
OR PLUGGING THE NOZZLE. THE STRAINER BOWL WILL BE NO LESS THAN 4" IN
HEIGHT. IT WILL HAVE A 20 MESH STAINLESS STEEL SCREEN. SHALL BE
SUPPLIED WITH A 304 STAINLESS STEEL MOUNTING BRACKET.

LEVEL SENSOR

THE LEVEL SENSOR ALERTS THE OPERATOR WHEN THE PRODUCT LEVEL IN THE
TANK DROPS TO NEAR EMPTY. THE FLOAT TYPE SENSOR WILL ACTIVATE THE
CAB CONTROL LIGHT AND AUDIBLE BUZZER TO ALERT THE OPERATOR. IT SHALL
ALSO SHUT DOWN THE SYSTEM TO PREVENT PUMP DAMAGE.

FLUSH ASSEMBLY

LOCATED AT THE SUCTION SIDE OF THE PUMP, BETWEEN THE "T" STRAINER AND
THE TANKS, IS A 1/2" THREE WAY PVC BALL VALVE ASSEMBLY. ITS FUNCTION
IS TO ALLOW FLOW FROM THE TANKS TO THE PUMP FOR NORMAL OPERATION. IT
ALSO ALLOWS FLOW VIA A GARDEN HOSE ADAPTER, THROUGH THE "T" STRAINER,
PUMP, AND SPRAY NOZZLES, TO FLUSH THE PRE-WET LIQUID FROM THE WORKING
COMPONENTS OF THE SYSTEM DURING PERIODS OF NON-USE.

PRESSURE REGULATOR

A .5" POLYPROPYLENE/STAINLESS STEEL ADJUSTABLE PRESSURE REGULATOR
VALVE SHALL BE LOCATED AT THE PUMP DISCHARGE TO ALLOW FOR PRECISE
CONTROL OF THE PRESSURE AND FLOW GOING TO THE SPRAY NOZZLE. EXCESS
PRESSURE/FLOW IS RETURNED TO THE TANK VIA .5" HOSE AND BULKHEAD
FITTING INSTALLED IN TANK.

PARTS MANUAL

INCLUDED WITH SYSTEM SHALL BE A COMPLETE PARTS MANUAL, INSTALLATION/
OPERATION/MAINTENANCE INSTRUCTIONS.

PRE-ASSEMBLY

TO FACILITATE EASY INSTALLATION BY TDOT PERSONNEL THE SYSTEM'S
COMPONENTS ARE TO BE ASSEMBLED AS MUCH AS IS PRACTICAL FOR SHIPPING.
EXAMPLES:
FITTINGS (2 EACH) TO BE INSTALLED IN TANK
MOUNTING PLATE TO HAVE PUMP/MOTOR ASSEMBLY AND JUNCTION BOX ATTACHED
TANK OUTLET VALVE TO BE ASSEMBLED AND WILL BE INSTALLED BY TDOT
FLUSH SYSTEM TO BE ASSEMBLED & CONNECTED TO "T" STRAINER AND WILL BE
INSTALLED BY TDOT.

DRAWINGS: INCLUDED WITH THE BID WILL BE DRAWINGS OF THE TANK, TANK
OUTLET VALVE ASSEMBLY, PLUMBING SCHEMATIC, WIRING SCHEMATIC, AND "L"
BRACKET DIMENSIONS.
SPECIFICATIONS FOR LINE ITEM 00020: FRAME MOUNTED PRE-WET SYSTEM
(65 GALLON TANK)

NOTE: UNIT MUST BE FULLY ASSEMBLED READY FOR IMMEDIATE USE

DESCRIPTION

THE FRAME MOUNTED PRE-WET SYSTEM IS DESIGNED TO BE CAPABLE OF
MAINTAINING A CONSISTENT RATIO OF LIQUID PRE-WET SOLUTIONS TO A
PRE-DETERMINED GRANULAR DEICING MATERIAL OUTPUT. THIS SYSTEM WILL
OPERATE IN CONJUNCTION WITH MANUAL HYDRAULIC FLOAT CONTROL VALVE
LOCATED IN CAB OF TRUCK (1 DAIL FOR SPINNER, 1 DIAL FOR AUGER).
OPERATOR CONTROLS SPEED OF AUGER & SPINNER IN RELATION TO THE SPEED
OF THE TRUCK. THE SYSTEM TANK AND PUMP UNIT ARE MOUNTED ON THE FRAME
RAIL OF THE TRUCK. THE TANK FRAME AND MOUNTING BRACKETS ARE MILD STEEL
HOT DIP GALVANIZED OR 304 STAINLESS STEEL FOR CORROSION PROTECTION AND
DESIGNED FOR EASY INSTALLATION. THE SYSTEM WILL OPERATE IN AUGER
REVERSE WITHOUT ANY BACK PRESSURE ON THE SYSTEM COMPONENTS. THE PUMP
UNIT IS MOUNTED ON THE SAME STEEL PLATE THAT THE TANK IS MOUNTED.

THE HYDRAULIC POWER UNIT (PUMP ENCLOSURE) IS MOUNTED IN A POSITION TO
BE EASILY ACCESSIBLE FOR INSPECTION AND MAINTENANCE. IT IS CONNECTED
IN SERIES WITH THE SPREADER'S AUGER MOTOR. THE CHEMICAL PUMP IS
CONNECTED TO THE SPRAY NOZZLES (2 EACH) WHICH ARE MOUNTED ON OR ABOVE
THE SPREADER'S DROP CHUTE. THE RESEVOIR TANK IS MOUNTED ON TWO FORMED
STEEL "L" BRACKETS.

COMPONENT CONFIGURATION

THE RESERVOIR TANK AND HYDRAULIC SYSTEM ENCLOSURE ARE MOUNTED ON A HOT
DIP GALVANIZED STEEL OR STAINLESS STEEL FRAME, MEETING
ASTM SPECIFICATION A-123, WHICH IS ATTACHED TO THE
FRAME RAIL TRUCK. THE STEEL CARRIER IS CONSTRUCTED
OF FORMED MILD STEEL OR 304 STAINLESS STEEL AND IS DESIGNED TO BE
PERMANENTLY MOUNTED TO THE FRAME OF THE TRUCK. THE CHEMICAL PUMP
OUTLET IS CONNECTED TO THE SPREADER MOUNTED SPRAY NOZZLES BY NYLON
RE-ENFORCED PVC HOSE. A QUICK DISCONNECT IS INCLUDED IN THE LIQUID
LINE TO FACILITATE EASY REMOVAL. THE SYSTEM CONTROLS ARE CAB-MOUNTED
AND ARE CONNECTED TO THE POWER UNIT WITH SHIELDED 4-WIRE CONTROL CABLE
WITH WEATHERPACK CONNECTORS. ALSO SHALL INCLUDE A NEMA 4X PLASTIC OR
FIBERGLASS JUNCTION BOX WITH MOISTURE TIGHT CABLE GRIPS.

HYDRAULIC POWER/PUMP MOTOR

MOUNTED ON A STAINLESS STEEL PLATE ALL HYDRAULIC/PUMP COMPONENTS ARE
ENCLOSED IN AN UNSEALED ROTATIONALLY MOLDED POLYETHYLENE OR STAINLESS
STEEL HOUSING. THE ENCLOSURE DIMENSIONS ARE APPROXIMATELY 18" X 7" X
12" (W X D X H). THE COVER IS HELD IN PLACE WITH TWO RUBBER LATCHES
MOUNTED WITH STAINLESS STEEL HARDWARE.
A 12" STAINLESS STEEL LANYARD ATTACHES THE LID TO THE
ENCLOSURE BOX. CONNECTED TO THE EXTERIOR OF THE ENCLOSURE, AT THE
SUCTION SIDE OF THE PRODUCT PUMP, IS A 12-MESH STAINLESS STEEL,
T-STRAINER FOR REMOVAL OF PARTICULATE MATTER, WHICH MAY HARM THE
PUMP OR RESTRICT FLOW THROUGH THE NOZZLES. THE SYSTEM INCORPORATES A
FULL FLOW BY-PASS VALVE THAT WILL DIVERT ALL HYDRAULIC FLOW, UP TO
15 GPM, FROM THE PUMP SYSTEM. TO ALLOW FOR PROPORTIONAL LIQUID DEICER
SOLUTION ADJUSTMENT THE SYSTEM USES AN ADJUSTABLE RATIO FLOW
CONTROLLER LOCATED IN THE POWER UNIT ENCLOSURE. AN ELECTRIC ACTIVATED
SOLENOID VALVE, CONTROLLED FROM THE CAB, OPERATES THE ON/OFF FUNCTION
OF THE SYSTEM ALLOWING HYDRAULIC FLOW THROUGH THE CONTROL BLOCK. THE
HYDRAULIC MOTOR IS CAST IRON, INTERNAL GEAR GEROTOR DESIGN WITH
.625 CID CAPACITY, DOUBLE-LIP TEFLON SEAL, WITH 1/2" NPT PORTS. IT IS
DIRECT COUPLED TO THE PRODUCT PUMP WHICH ELIMINATES THE NEED FOR A
LOVEJOY TYPE COUPLER. THE PRODUCT PUMP, BRONZE ROTARY GEAR, POSITIVE
DISPLACEMENT, WITH STAINLESS STEEL SHAFT, CARBON BEARINGS, HAS A FLOW
RATE OF 8.7 GPM AT 20 PSI WITH 4.5 GALLONS OF HYDRAULIC FLOW.
ALL HYDRAULIC HOSES IN THE ENCLOSURE ARE FLEXIBLE.

TANK

THE 65 GALLON TANK IS CONSTRUCTED OF ROTATIONALLY MOLDED HIGH-DENSITY
POLYETHYLENE, WHICH IS UV STABILIZED. TANKS ARE DESIGNED TO HOLD
LIQUID PRE-WET MATERIALS WITH SPECIFIC GRAVITY OF UP TO 16 LBS. PER
GALLON. A PVC/POLYPROPYLENE VALVE IS PROVIDED AT THE TANK OUTLET TO
THE PUMP. THE TANK IS EQUIPPED WITH A 5" TOP FILL OPENING WITH VENTED
LID. THE TANK IS ATTACHED WITH TWO HEAVY DUTY GALVANIZED
STEEL OR STAINLESS STEEL ADJUSTABLE BANDS. INSTALLED IN THE
TANK IS A LEVEL SWITCH WHICH IS CONNECTED TO THE CAB CONTROL FOR
AUTOMATIC SYSTEM SHUTDOWN WHEN THE TANK IS EMPTY. TANKS SHALL NOT
EXCEED 23" DIAMETER X 43" LENGTH. COLOR TO BE WHITE.

SPRAY NOZZLES

CONSTRUCTED OF BRASS, THE SPRAY NOZZLE IS DESIGNED TO MAINTAIN
A 120 DEGREE FAN SPRAY THROUGHOUT THE SYSTEM CHEMICAL FLOW RATE.
A 304 STAINLESS STEEL NOZZLE MOUNTING PLATE, 16 GUAGE 2" X 3.5" WITH
A 11/16" SPACED CENTER 1.25" FROM ONE END TO BE INCLUDED.

FITTINGS AND VALVES

ALL CHEMICAL PLUMBING FITTINGS AND VALVES ARE FLEXIBLE TYPE PVC
OR POLYPROPLENE. ALL HOSE IS NYLON REINFORCED PVC. THE SYSTEM
USES AN ACCESSIBLE IN-LINE STRAINER WITH 20 MESH SCREEN. THE FILL
POINT USES A 1" QUICK CONNECT POLYPROPYLENE COUPLING AND IS A BOTTOM
FILL SYSTEM. THE TANK IS VENTED FOR BOTTOM FILL. HOSE CLAMPS TO
BE STAINLESS STEEL. TANK VALVE WILL BE .75" POLYPROPLENE 3-WAY SIDE
LOAD TYPE WITH 1" FEMALE QUICK COUPLE CONNECTION AND DUST PLUG, .75"
BRASS NIPPLE, AND 1/2 POUND CHECK VALVE TO AID IN MAINTAINING PUMP.
A .5" "T" STRAINER WILL BE PLACED IN LINE BETWEEN THE PUMP SUCTION AND
THE TANK. THIS WILL PREVENT PARTICULATE MATTER FROM DAMAGING THE PUMP
OR PLUGGING THE NOZZLE. THE STRAINER BOWL WILL BE NO LESS THAN 4" IN
HEIGHT. IT WILL HAVE A 20 MESH STAINLESS STEEL SCREEN. SHALL BE
SUPPLIED WITH A 304 STAINLESS STEEL MOUNTING BRACKET.

LEVEL SENSOR

THE LEVEL SENSOR ALERTS THE OPERATOR WHEN THE PRODUCT LEVEL IN THE
TANK DROPS TO NEAR EMPTY. THE FLOAT TYPE SENSOR WILL ACTIVATE THE
CAB CONTROL LIGHT AND AUDIBLE BUZZER TO ALERT THE OPERATOR. IT SHALL
ALSO SHUT DOWN THE SYSTEM TO PREVENT PUMP DAMAGE.

FLUSH ASSEMBLY

LOCATED AT THE SUCTION SIDE OF THE PUMP, BETWEEN THE "T" STRAINER AND
THE TANKS, IS A 1/2" THREE WAY PVC BALL VALVE ASSEMBLY. ITS FUNCTION
IS TO ALLOW FLOW FROM THE TANKS TO THE PUMP FOR NORMAL OPERATION. IT
ALSO ALLOWS FLOW VIA A GARDEN HOSE ADAPTER, THROUGH THE "T" STRAINER,
PUMP, AND SPRAY NOZZLES, TO FLUSH THE PRE-WET LIQUID FROM THE WORKING
COMPONENTS OF THE SYSTEM DURING PERIODS OF NON-USE.

PRESSURE REGULATOR

A .5" POLYPROPYLENE/STAINLESS STEEL ADJUSTABLE PRESSURE REGULATOR
VALVE SHALL BE LOCATED AT THE PUMP DISCHARGE TO ALLOW FOR PRECISE
CONTROL OF THE PRESSURE AND FLOW GOING TO THE SPRAY NOZZLE. EXCESS
PRESSURE/FLOW IS RETURNED TO THE TANK VIA .5" HOSE AND BULKHEAD
FITTING INSTALLED IN TANK.

PARTS MANUAL

INCLUDED WITH SYSTEM SHALL BE A COMPLETE PARTS MANUAL, INSTALLATION/
OPERATION/MAINTENANCE INSTRUCTIONS.

PRE-ASSEMBLY

TO FACILITATE EASY INSTALLATION BY TDOT PERSONNEL THE SYSTEM'S
COMPONENTS ARE TO BE ASSEMBLED AS MUCH AS IS PRACTICAL FOR SHIPPING.
EXAMPLES:
FITTINGS (2 EACH) TO BE INSTALLED IN TANK
MOUNTING PLATE TO HAVE PUMP/MOTOR ASSEMBLY AND JUNCTION BOX ATTACHED
TANK OUTLET VALVE TO BE ASSEMBLED AND WILL BE INSTALLED BY TDOT
FLUSH SYSTEM TO BE ASSEMBLED & CONNECTED TO "T" STRAINER AND WILL BE
INSTALLED BY TDOT.

DRAWINGS: INCLUDED WITH THE BID WILL BE DRAWINGS OF THE TANK, TANK
OUTLET VALVE ASSEMBLY, PLUMBING SCHEMATIC, WIRING SCHEMATIC, AND "L"
BRACKET DIMENSIONS.
SPECIFICATIONS FOR LINE ITEM 00021: SPREADER, AUGER TYPE
304 STAINLESS STEEL

1) TYPE - SINGLE AUGER

2) WIDTH - 96"

3) HOPPER - 7 GAUGE 304 STAINLESS STEEL, CONTINUOUS WELD

4) COVER PLATE & - MANUFACTURED FROM 7 GAUGE 304 STAINLESS STEEL,
DESIGNED FOR EASY CLEAN OUT FROM BOTH TOP & BOTTOM.
REAR PLATE ALSO TO SERVE AS A SPILL PLATE OVER
AUGER FOR DUMPING OVER & ACROSS THE SPREADER HOPPER
CLEAN-OUT & DUMPING FEATURES SHAL BE ACCOMPLISHED
WITHOUT THE USE OF TOOLS, PINS, LATCHES, ETC.,
SHALL BE SECURED TO SPREADER BY MANUFACTURER DESIGN

5) ANTI-SPILL COVER PLATE - MUST PREVENT MATERIAL FREE FLOW WHEN
AUGER IS IDLE. REMOVABLE WITHOUT TOOLS.

6) TAILGATE SPILL PLATE - MANUFACTURED FROM 7 GAUGE MINIMUM STEEL,
PLATE DESIGNED FOR ATTACHING TO INSIDE
TAILGATE AT ENDS TO PREVENT MATERIAL
SPILLAGE AT END OF SPREADER WHEN TAILGATE
IS AT IT'S MAXIMUM OPENING FOR MATERIAL
SPREADING.

7) AUGER - FULL WIDTH - 7 FT., MANUFACTURED FROM MINIMUM 2 3/8" O.D.
SCHEDULE 80 PIPE. 6" SINGLE, ONE-WAY DIRECTIONAL STEP
FLITE OR CONTINUOUS WITH 3/8" FLITES, DESIGNED TO SEND
MATERIAL TO EXTREME LEFT.

*NOTE: AUGER MUST MOVE SALT TO THE EXTREME LEFT, AN OFFSET
TO BRACE WILL NOT BE ACCEPTABLE. SPINNER MUST BE
VISIBLE FROM DRIVER'S MIRROR. (REVERSE FLIGHT WILL
NOT BE ACCEPTABLE)

8) AUGER DRIVE - HYDRAULIC MOTOR, CHARLYNN, MOUNTED TO A 5:1 REDUCTION
WORM GEAR TYPE, GEAR BOX SPEED REDUCER DEVELOPING
4,224 INCH POUNDS OF TORQUE.

*NOTE: CHAIN AND SPROCKET UNACCEPTABLE

9) BEARINGS - SELF-ALIGNING, SEALED, DUST-PROOF GREASE FITTINGS.
MINIMUM 1 1/4" I.D.

10) SPINNER (SINGLE) - 18" MINIMUM, 304 STAINLESS STEEL FORMED FOR LOW
TRAJECTORY WITH SIX (6) STAINLESS STEEL
3/16" REPLACEABLE FINS. ADJUSTABLE SPREAD
LEFT TO CENTER TO RIGHT. SPINNER TO BE LOCATED
EXTREME LEFT SIDE OF SPREADER.

11) SPINNER SHIELD - SHIELD TO BE PROVIDED TO PREVENT SALT FROM
STRIKING TRUCK.

12) "FREE FLOATING" SPINNER MUST BE CENTERED AND SALT DISCHARGE MUST
BE FREE FLOATING AND REMAIN PARALLEL TO ROAD. THIS WILL ALLOW
SPINNER TO PIVOT WHEN DUMPING SALT (AFTER THE STORM) BACK TO THE
STOCK PILE.
NOTE: SPINNER MUST CLEAR SPREADER TROUGH WHEN TRUCK BED IS AT
FULL DUMP ANGLE. PARRALLEL ARM MUST BE PROPER LENGTH.

13) HOSE HYDRAULIC - WIRE BRAID PRESSURE & RETURN OF SUFFICIENT LENGTH
TO HOOK UP SPREADER TO REAR OF TRUCK'S CENTRAL
HYDRAULIC SYSTEM. HOSE END TO BE FURNISHED LESS
QUICK DISCONNECT COUPLER.

14) HOSE SIZE - SPINNER: 1/2"
AUGER: 1/2"
RETURN LINE: 3/4"

15) OTHER REQUIREMENTS - SPREADER TO BE DELIVERED WITH ALL NECESSARY
COMPONENTS; BRACKETS, HYDRAULIC HOSES, &
ACCESSORIES NECESSARY TO FORM A COMPLETE UNIT
FOR INSTALLATION & PROPER OPERATION.

16) THROUGH MOUNTING - QUICK ATTACH OR REMOVAL WITH NO PARTS TO DETACH
HEAVY DUTY STEEL ROD LATCHES

17) COLOR - BLACK (NOTE: ANY COMPONENTS MFG. FROM GRAD 304 STAINLESS
STEEL DO NOT REQUIRE PAINT.)

18) WARRANTY - ONE (1) YEAR, 100% PARTS & LABOR AGAINST DEFECTS IN
MATERIALS & WORKMANSHIP.

19) GENERAL - RESPONSIVE VENDORS BIDDING "OR EQUAL" BRANDS & MODELS
ARE REQUIRED TO OUTLINE ON A SPECIFICATION SHEET, THE
FEATURES FOR THEIR BRAND/MODEL.

MANUFACTURER'S STANDARD MODEL MAY BE MODIFIED AS
NECESSARY TO MEET ACCEPTABLE MINIMUM SPECIFICATIONS.
SUCCESSFUL BIDDER MUST PROVIDE A MANUFACTURER'S LETTER
AS TO ALL MODIFICATIONS FOR THE MODEL PROPOSED.

NOTE: SPREADER WILL OPERATE FROM A CENTRAL HYDRAULIC SYSTEM.
HYDRAULIC PUMP, RESERVOIR, FILTER & SPREADER CONTROL
ARE NOT REQUIRED.

20) MANUFACTURER'S DESIGN - SPREADER DESIGNED SO SPREADER'S TOP COVER
CAN OPEN WHEN TRUCK'S DUMP BED TAILGATE
IS CLOSED. (4" SPACER REQUIRED BETWEEN
TRUCK TAILGATE & SPREADER)

21) PILOT MODEL - DEPARTMENT OF TRANSPORTATION RESERVES THE RIGHT TO
REQUIRE ONE PILOT MODEL TO NASHVILLE F.O.B. DELIVERY
POINT.

22) MANUALS - PARTS & MOUNTINMG INSTRUCTIONS

SPECIFICATIONS FOR LINE ITEM 00022: SPREADER, AUGER TYPE
201 STAINLESS STEEL

1) TYPE - SINGLE AUGER

2) WIDTH - 96"

3) HOPPER - 7 GAUGE 201 STAINLESS STEEL, CONTINUOUS WELD

4) COVER PLATE & - MANUFACTURED FROM 7 GAUGE 201 STAINLESS STEEL,
DESIGNED FOR EASY CLEAN OUT FROM BOTH TOP & BOTTOM.
REAR PLATE ALSO TO SERVE AS A SPILL PLATE OVER
AUGER FOR DUMPING OVER & ACROSS THE SPREADER HOPPER
CLEAN-OUT & DUMPING FEATURES SHAL BE ACCOMPLISHED
WITHOUT THE USE OF TOOLS, PINS, LATCHES, ETC.,
SHALL BE SECURED TO SPREADER BY MANUFACTURER DESIGN

5) ANTI-SPILL COVER PLATE - MUST PREVENT MATERIAL FREE FLOW WHEN
AUGER IS IDLE. REMOVABLE WITHOUT TOOLS.

6) TAILGATE SPILL PLATE - MANUFACTURED FROM 7 GAUGE MINIMUM STEEL,
PLATE DESIGNED FOR ATTACHING TO INSIDE
TAILGATE AT ENDS TO PREVENT MATERIAL
SPILLAGE AT END OF SPREADER WHEN TAILGATE
IS AT IT'S MAXIMUM OPENING FOR MATERIAL
SPREADING.

7) AUGER - FULL WIDTH - 7 FT., MANUFACTURED FROM MINIMUM 2 3/8" O.D.
SCHEDULE 80 PIPE. 6" SINGLE, ONE-WAY DIRECTIONAL STEP
FLITE OR CONTINUOUS WITH 3/8" FLITES, DESIGNED TO SEND
MATERIAL TO EXTREME LEFT.

*NOTE: AUGER MUST MOVE SALT TO THE EXTREME LEFT, AN OFFSET
TO BRACE WILL NOT BE ACCEPTABLE. SPINNER MUST BE
VISIBLE FROM DRIVER'S MIRROR. (REVERSE FLIGHT WILL
NOT BE ACCEPTABLE)

8) AUGER DRIVE - HYDRAULIC MOTOR, CHARLYNN, MOUNTED TO A 5:1 REDUCTION
WORM GEAR TYPE, GEAR BOX SPEED REDUCER DEVELOPING
4,224 INCH POUNDS OF TORQUE.

*NOTE: CHAIN AND SPROCKET UNACCEPTABLE

9) BEARINGS - SELF-ALIGNING, SEALED, DUST-PROOF GREASE FITTINGS.
MINIMUM 1 1/4" I.D.

10) SPINNER (SINGLE) - 18" MINIMUM, 201 STAINLESS STEEL FORMED FOR LOW
TRAJECTORY WITH SIX (6) STAINLESS STEEL
3/16" REPLACEABLE FINS. ADJUSTABLE SPREAD
LEFT TO CENTER TO RIGHT. SPINNER TO BE LOCATED
EXTREME LEFT SIDE OF SPREADER.

11) SPINNER SHIELD - SHIELD TO BE PROVIDED TO PREVENT SALT FROM
STRIKING TRUCK.

12) "FREE FLOATING" SPINNER MUST BE CENTERED AND SALT DISCHARGE MUST
BE FREE FLOATING AND REMAIN PARALLEL TO ROAD. THIS WILL ALLOW
SPINNER TO PIVOT WHEN DUMPING SALT (AFTER THE STORM) BACK TO THE
STOCK PILE.
NOTE: SPINNER MUST CLEAR SPREADER TROUGH WHEN TRUCK BED IS AT
FULL DUMP ANGLE. PARRALLEL ARM MUST BE PROPER LENGTH.

13) HOSE HYDRAULIC - WIRE BRAID PRESSURE & RETURN OF SUFFICIENT LENGTH
TO HOOK UP SPREADER TO REAR OF TRUCK'S CENTRAL
HYDRAULIC SYSTEM. HOSE END TO BE FURNISHED LESS
QUICK DISCONNECT COUPLER.

14) HOSE SIZE - SPINNER: 1/2"
AUGER: 1/2"
RETURN LINE: 3/4"

15) OTHER REQUIREMENTS - SPREADER TO BE DELIVERED WITH ALL NECESSARY
COMPONENTS; BRACKETS, HYDRAULIC HOSES, &
ACCESSORIES NECESSARY TO FORM A COMPLETE UNIT
FOR INSTALLATION & PROPER OPERATION.

16) THROUGH MOUNTING - QUICK ATTACH OR REMOVAL WITH NO PARTS TO DETACH
HEAVY DUTY STEEL ROD LATCHES

17) COLOR - BLACK (NOTE: ANY COMPONENTS MFG. FROM GRAD 201 STAINLESS
STEEL DO NOT REQUIRE PAINT.)

18) WARRANTY - ONE (1) YEAR, 100% PARTS & LABOR AGAINST DEFECTS IN
MATERIALS & WORKMANSHIP.

19) GENERAL - RESPONSIVE VENDORS BIDDING "OR EQUAL" BRANDS & MODELS
ARE REQUIRED TO OUTLINE ON A SPECIFICATION SHEET, THE
FEATURES FOR THEIR BRAND/MODEL.

MANUFACTURER'S STANDARD MODEL MAY BE MODIFIED AS
NECESSARY TO MEET ACCEPTABLE MINIMUM SPECIFICATIONS.
SUCCESSFUL BIDDER MUST PROVIDE A MANUFACTURER'S LETTER
AS TO ALL MODIFICATIONS FOR THE MODEL PROPOSED.

NOTE: SPREADER WILL OPERATE FROM A CENTRAL HYDRAULIC SYSTEM.
HYDRAULIC PUMP, RESERVOIR, FILTER & SPREADER CONTROL
ARE NOT REQUIRED.

20) MANUFACTURER'S DESIGN - SPREADER DESIGNED SO SPREADER'S TOP COVER
CAN OPEN WHEN TRUCK'S DUMP BED TAILGATE
IS CLOSED. (4" SPACER REQUIRED BETWEEN
TRUCK TAILGATE & SPREADER)

21) PILOT MODEL - DEPARTMENT OF TRANSPORTATION RESERVES THE RIGHT TO
REQUIRE ONE PILOT MODEL TO NASHVILLE F.O.B. DELIVERY
POINT.

22) MANUALS - PARTS & MOUNTINMG INSTRUCTIONS


SPECIFICATIONS FOR LINE ITEM 00023: TAILGATE SPREADER, BELT DRIVEN

DESCRIPTION

SHALL BE A DUMP BODY MOUNTED CROSS CONVEYOR WITH CAPABILITY TO RUN IN
EITHER DIRECTION TO UNLOAD CONTROLLED AMOUNTS OF MATERIAL FROM A
MOVING TRUCK. CONVEYOR SHALL BE SELF-LEVELING WITH HYDRAULIC DRIVE.
GATES AT THE END OF THE CONVEYOR SHALL BE ADJUSTABLE TO CONTROL THE
DISCHARGE RATE. DISCHARGE RATE WILL ALSO BE CONTROLLED BY A VARIBLE
SPEED CONTROL ON THE DRIVE MOTOR. MACHINE CAN BE EQUIPPED WITH A
SPINNER MECHANISM TO PERMIT SPREADING OF ICE CONTROL MATERIALS WHEN
NEEDED. UNIT SHALL BE APPROX. 102" WIDE WITH ADJUSTABLE MOUNTING
HARDWARE TO ACCOMMODATE DUMP BODIES WITH OUTSIDE FROM 94" TO 96" WIDE.

MACHINE SHALL BE EQUIPPED WITH AN 18" WIDE BELT RIVETED TO 1/4" X 1"
CROSS BARS FOR POSITIVE MOVEMENT OF MATERIALS. BELT TO BE HEAT & OIL
RESISTANT WITH A TEMPERATURE RANGE OF -10 DEGREES F TO 350 DEGREES F.
BOTTOM PANEL WILL BE 7 GAUGE MILD STEEL FOR CONTINUOUS SUPPORT OF THE
CHAIN ASSEMBLY. POSITIVE SPROCKET DRIVE ASSURES CONTINUOUS MATERIAL
FLOW UNDER VARYING LOADS. CONVEYOR FRAME SHALL B E 7 GAUGE MILD STEEL
WELDED TO FORM A DURABLE CONTAINER FOR MATERIAL TO BE SPREAD &
SUPPORT FOR ALL MOVING PARTS. ANTI-FLOW COMPONENTS SHALL BE PROVIDED
FOR INSTALLATION IN THE DUMP BOX TO PREVENT SPILLING OF MATERIAL
AROUND THE TAILGATE & FROM AN OPEN METERING GATE WHEN CONVEYOR IS NOT
IN USE. BOTH ENDGATES SHALL BE EQUIPPED WITH HINGES & A FRAME TO
SWING FREE FOR MAXIMUM DISCHARGE RATES OR OVERSIZED FEED GATES.

CONTROLS

SHALL BE FOR CAB INSTALLATION. CONTROL VALVE TO BE PRESSURE
COMPENSATED, HAVING INDEPENDENT VARIABLE SPEED CONTROL FOR CONVEYOR &
SPINNER, A MASTER ON/OFF CONTROL, & BUILT-IN PRESSURE RELIEF VALVE
SET AT 1500 PSI. ALSO TO HAVE OPERATOR'S CONTROL LOCATED ON CONVEYOR
SYSTEM AT REAR OF CONVEYOR WITH ON, OFF AND REVERSE.

HYDRAULIC HOSE

ALL FITTINGS & HOSE REQUIRED TO MAKE COMPLETE INSTALLATION SHALL BE
FURNISHED, INCLUDING THREE (3) NO-DRIP TYPE, QUICK-DISCONNECT COUPLERS
ALL PRESSURE FITTINGS & HOSES TO HAVE A MINIMUM RATING OF 2000 PSI IN
ACCORDANCE WITH SAE STANDARDS.

PAINT

PRIOR TO THE ASSEMBLY OF THE UNIT, ALL COMPONENTS ARE TO BE
INDIVIDUALLY CLEANED WITH AN IRON PHOSPHATE TREATMENT. UPON COMPLETION
OF THE CLEANING PROCESS, EXPOSED HOPPER SEAMS NOT WELDED ARE TO BE
SEALED. ALL COMPONENTS ARE THEN PRIME PAINTED. NEXT, THE PLURAL-
COMPONENT URETHANE FINISH COAT IS TO BE APPLIED ON MAIN HOPPER
COMPONENTS & ON BOLT-ON COMPONENTS. ALL COMPONENTS & HOPPER ARE TO
BE OVEN CURED & THEN COMPLETELY ASSEMBLED.

OPERATION & MAINTENANCE MANUAL

MANUAL IS TO BE FURNISHED WITH EACH UNIT COVERING OPERATION,
MAINTENANCE & PARTS LISTING FOR THE UNIT.


SPECIFICATIONS FOR LINE ITEM 00024: INFRARED ROAD TEMPERATURE SYSTEM

1) ACCURACY - +/- 2 DEGREE F, OR 1% OF FULL SCALE

2) REPEATABILITY - +.5% OF FULL SCALE

3) EMISSIVITY - FACTORY CALIBRATED AT .96

4) CALIBRATION - LIFETIME FACTORY DIGITAL CALIBRATION

5) FIELD OF VIEW - 10 DEGREES

6) OPERATING VOLTAGE - 12V DC NOMINAL

7) READOUT SCALES - FAHRENHEIT

8) ROAD TEMPERATURE DISPLAY RANGE - -40 TO +212 DEGREES F.

9) AIR TEMPERATURE DISPLAY RANGE - -40 TO +122 DEGREES F.

10) RESPONSE TIME - 100 MILLISECONDS, DAMPENED TO 500 MILLISECONDS

11) POWER CONSUMPTION - 200 MILLIAMPS

12) CABLE - 3.65 METER (12 FT.), SHIELDED

13) WEIGHT - SENSOR 7 OZ., DISPLAY 4 OZ.

14) SENSOR FEATURES - 4" LONG ANODIZED ALUMINUM ENCLOSURE, EMI/RFI
SHIELDED ELECTRONICS, TRUCK MIRROR MOUNTING
STANDARD.

15) DISPLAY FEATURES - STANDARD SIZE GAUGE ENCLOSURE. ILLUMINATED
L.E.D. DIGITAL DISPLAY. THRESHOLD VISUAL ALERT
SELECTABLE CELSIUS OR FAHRENHEIT.

16) VISUAL DISPLAY INSIDE OF CAB


SPECIFICATIONS FOR LINE ITEM 00025 AND 00026: RUST PREVENTATIVE

1) ENCAPSULANT - HIGH-STRENGTH POLYMER WITH APPROPRIATE CHARGE TO
ENCAPSULATE SALTS AND CHLORIDES

2) DRIED FLEXIBLE FILM THICKNESS - 2-3 MILS, NON-TACKY

3) ADDITIVE PACKAGE - E.P. AGENT, ANTI-RUST, ANTI-OXIDATION,
CORROSION INHIBITOR

4) MOISTURE AND WATER RESISTANCE - INSOLUBLE, TOTALLY RESISTANT

5) ELEMEMT RESISTANCE - HEAT, RAIN, WATER PRESSURE AND ACID

6) DRYING TIME - 60-120 MINUTES

7) API SPECIFIC GRAVITY - 7.5

8) VISCOSITY - SPRAYABLE LIQUID

9) FLASH POINT AND METHOD - >110 DEGREES F TCC


SPECIFICATIONS FOR LINE ITEM 00027: RUST PREVENTATIVE SPRAYER


1) 3 GALLON CAPACITY

2) VITON SEALS AND GASKETS

3) BRASS NOZZLE AND ASSEMBLY WITH T-JET .5 GPM NOZZLE

4) BRASS SHUT OFF

5) HOSE IS TO BE ATTACHED AT THE FACTORY TO PREVENT HAZARDS
OF ASSEMBLY

6) TANK - STEEL INTERIOR AND EXTERIOR COATED WITH TRI-POXY COATING


NOTE: DEPARTMENT OF TRANSPORTATION FACILITIES WILL PROVIDE EQUIPMENT
AND OPERATOR TO UNLOAD ALL ITEMS. PLEASE CONTACT ORDERING
FACILITY 24 HOURS PRIOR TO DELIVERY.


Vendor Name and Address Business Ownership Contract Details
Swenson Spreader Llc
127 Walnut St
Lindenwood, IL 61049-0127
Vendor Contact: Ryan King
Contact Phone: (888)825-7323
Small: No
Minority: No
Woman-Owned: No
Contract No: 4038662
Payment Terms: NONE
Delivery: 120 DAYS ARO
Contract extended to Local Governments & State Agencies
Flink Co
502 N Vermillion
Streator, IL 61364
Vendor Contact: Duane Kruger
Contact Phone: (815)673-4321
Small: Yes
Minority: No
Woman-Owned: No
Contract No: 4038664
Payment Terms: NONE
Delivery: 120 DAYS ARO
Contract extended to Local Governments & State Agencies
Sprayer Specialties, Inc.
4151 Se Capital Circle
Grimes, IA 50111
Vendor Contact: Robert Killian
Contact Phone: (800)351-1587
Small: No
Minority: No
Woman-Owned: No
Contract No: 4038663
Payment Terms: NONE
Delivery: 90 DAYS ARO
Contract extended to Local Governments & State Agencies
Rhomar Industries Inc.
2107 E Rockhurst St
Springfield, MO 65802-6522
Vendor Contact: Davis Slayden
Contact Phone: (417)866-5592
Small: Yes
Minority: No
Woman-Owned: No
Contract No: 4038665
Payment Terms: NONE
Delivery: 14 DAYS ARO
Contract extended to Local Governments & State Agencies

Contract Items and Services for SWC #206

Unless specified elsewhere, ship to: Statewide
Commodity Codes in hypertext links below, if clicked, will lead to a picture of the product!

SWC No.

Solic. No.
Contract No. Line No. Commodity Code

Description
Unit Unit Price Discount Off
Catalog Price
206
2061865
4038662 00001 765-54-056968
Spreaders, Salt, V-box, 1.8 Cu. Yd. Designed To Fit Onto Pickup Truck. New And Meeting The Attached Minimum Specifications.
EA $4,054.68000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00002 943-78-056969
Tanks, Polyethylene, Dual 15 Gallons, For Applying Calcium Chloride To Spinner To Include All Items Necessary For Application.
EA $1,312.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00003 765-54-056970
Spreaders, Salt, V-box, 3 Cu. Yd. Designed To Fit 10,000 Gvwr Flatbed Or Dump Truck. New And Meeting The Attached Minimum Applications
EA $5,378.13000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00004 943-78-056971
Tanks, Polyethylene, Dual 30 Gallons, For Applying Calcium Chloride To Spinner To Include All Items Necessary For Applicaton.
EA $1,312.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00005 765-54-043548
Spreader, Salt, V-box Slide-in Hopper For 37,000 Gvwr Dump Truck With 10 Ft. Body. New And Meeting The Attached Minimum Specifications. Spreader Hopper Shall Be Designed To Fit Into State Owned Dump Body Which Is Approx. 10'l X 84"w X 36"h. Dump Bed Has Hoist Well, Successful Vendor Must Measure. Dump Body Can Be Made Available
EA $7,854.98000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00006 943-78-056973
Tanks, Polyethylene, 75 Gallon With Hydraulic Drive For Applying Calcium Chloride To Spinner. To Include All Necessary Hardware For Installation.
EA $1,535.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00007 765-54-043549
Spreader, Salt, V-box Slide-in Hopper For 64,000 Gvwr Dump Truck With 14 Ft. Body. New And Meeting The Attached Minimum Specifications. Spreader Hopper Shall Be Designed To Fit Into State Owned Dump Body Which Is 14'l X 96"w X 38"h. Dump Bed Has Hoist Well. Successful Vendor Must Measure. Dump Body Can Be Made Available At Tdot
EA $8,840.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00008 943-78-056974
Tanks, Polyethylene, 90 Gallon Hydraulic Drive For Applying Calcium Chloride To Spinner. To Include All Necessary Hardware For Installation.
EA $1,535.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00009 765-54-056975
Spreader, Salt, V-box Slide-in Hopper, For 64,000 Gvwr Dump Truck With 16 Ft. Body. New And Meeting The Attached Minimum Specifications. Spreader Hopper Shall Be Designed To Fit Into State Owned Dump Body Which Is 16'l X 96"w X 46"h. Dump Body Can Be Made Available At Tdot Regional Facility For Inspection. Dump Bed Has Hoist Well.
EA $9,710.28000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00010 943-78-056976
Tanks, Polyethlene, 90 Gallon With Hydraulic Drive. For Applying Calcium Chloride To Spinner.
EA $1,535.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00019 765-54-067664
Tailgate Mounted Prewet System, 135 Gallon. New And Meeting The Attached Minimum Specificaions.
EA $3,201.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00020 765-54-056979
Frame Mounted Prewet System Tank (65 Gallon Tank). New And Meeting The Attached Minimum Specifications.
EA $3,041.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00021 765-54-056982
Spreader, Road Salt, Auger Type For Dump Tailgate, 304 Stainless Steel. New And Meeting The Attached Minimum Specifications.
EA $1,993.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00022 765-54-072293
Spreaders, Road Salt, Auger Type, Dump Tail Gate, 201 Stainless Steel New And Meeting The Attached Minimum Specifications.
EA $1,993.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038662 00023 765-54-056983
Tailgate Spreader, Belt Driven For Shoulder Spreading Of Material. New And Meeting The Attached Minimum Specifications.
EA $4,289.00000 N/A
Vendor: Swenson Spreader Llc Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038664 00024 765-54-056984
Infrared Road Temperature Measuring System. New And Meeting The Attached Minimum Specifications
EA $494.44000 N/A
Vendor: Flink Co Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038663 00011 765-54-056977
Calcium Chloride, Salt Brine, Or Liquid Herbicide Applicator W/ground Speed Control. Minimum 200 Gallon. Designed To Fit Onto A 1/2 Ton Pickup Truck.
EA $5,919.00000 N/A
Vendor: Sprayer Specialties, Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038663 00012 765-54-056978
Calcium Chloride, Salt Brine, Or Liquid Herbicide Applicator W/ground Speed Control. Minimum 500 Gallon. To Fit On A Flatbed Or 10,000 Gvwr Dump Truck.
EA $6,870.00000 N/A
Vendor: Sprayer Specialties, Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038663 00013 765-54-067658
Calcium Chloride, Salt Brine, Or Liquid Herbicide Applicator W/ground Speed Control. Minimum 1,000 Gallon. To Fit A 37,000 Gvwr Dump Truck
EA $9,812.00000 N/A
Vendor: Sprayer Specialties, Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038663 00014 765-54-067659
Pump, Gas Engine-driven, Cast Iron, In Place Of Hydraulic Pump For Above Line Item. Vendor To Bid The Cost Of The Upgrade For The Pump Only.
EA $689.00000 N/A
Vendor: Sprayer Specialties, Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038663 00015 765-54-067660
Calcium Chloride, Salt Brine, Or Liquid Herbicide Applicator W/ground Speed Control. Minimum 1800 Gallon. To Fit On A 46,000 Gvwr Tandem Dump Truck
EA $11,495.00000 N/A
Vendor: Sprayer Specialties, Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038663 00016 765-54-067661
Pump, Gas Engine-driven, Cast Iron, In Place Of Hydraulic Pump For Above Line Item. Vendor To Bid The Cost Of The Upgrade For The Pump Only.
EA $689.00000 N/A
Vendor: Sprayer Specialties, Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038663 00017 765-54-067662
Calcium Chloride, Salt Brine, Or Liquid Herbicide Applicator W/ground Speed Control. Minimum 2600 Gallons. To Fit A 74,000 Gvwr Tri-axle Dump Truck
EA $12,756.00000 N/A
Vendor: Sprayer Specialties, Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038663 00018 765-54-067663
Pump, Gas Engine-driven, Cast Iron, In Place Of Hydraulic Pump For Above Line Item. Vendor To Bid The Cost Of The Upgrade For The Pump Only.
EA $689.00000 N/A
Vendor: Sprayer Specialties, Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038665 00025 765-54-056985
Rust Preventative (24 Gallons) Packaged In 4 - 6 Gallon Pails Meeting The Attached Specifications
EA $39.95000 N/A
Vendor: Rhomar Industries Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038665 00026 765-54-056986
Rust Preventative Packaged In 55 Gallon Drum Meeting The Attached Specifications
EA $38.95000 N/A
Vendor: Rhomar Industries Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies

206
2061865
4038665 00027 765-54-056987
3 Gallon Sprayer/applicator. New And Meeting The Attached Minimum Specifications.
EA $79.95000 N/A
Vendor: Rhomar Industries Inc. Recycle Content: N/A
Contract extended to Local Governments & State Agencies